Difference between revisions of "Offline Monitoring Data Validation PrimEx"
(→TEMP: To Do) |
(→General Notes) |
||
Line 37: | Line 37: | ||
=== General Notes === | === General Notes === | ||
* Reference runs are listed for each target type | * Reference runs are listed for each target type | ||
− | ** Be Empty: 110453 ( | + | ** Be Empty: 110453 (left out of monitoring launches 01-11) |
** Be Full: 110551 | ** Be Full: 110551 | ||
** He Empty: 111917 | ** He Empty: 111917 |
Revision as of 12:36, 10 January 2024
This page contains the procedure for checking if PrimEx-η production runs are of good quality and can be used for physics analysis. This page is a work in progress and should not (yet) be used as a reference
Contents
[hide]Run Periods
- RunPeriod-2019-01 Validation (PrimEx-η Phase I)
- RunPeriod-2021-08 Validation (PrimEx-η Phase II)
- RunPeriod-2022-08 Validation (PrimEx-η Phase III)
Procedure
For each production run, do the following:
- Go to the Offline Run Browser page.
- Follow the steps outlined in the checklist below.
- Workers should check each plot for their assigned subsystem and leave notes in the corresponding spreadsheet if any significant deviations are seen
- On the spreadsheet, enter "Y" in the "Overall Quality" field if all monitoring histograms are acceptable, otherwise enter "N"
- We will iterate this procedure until the process converges
Expert Actions
- Certify that each subsystem is okay
- Set run status in RCDB based on monitoring results
- (script provided)
Run Statuses
- -1 - unchecked
- 0 - rejected (not physics-quality)
- 1 - approved
- 2 - approved long/"mode 8" data
- 3 - calibration / systematic studies
Checklist
Example Monitoring Spreadsheet (template, incomplete)
General Notes
- Reference runs are listed for each target type
- Be Empty: 110453 (left out of monitoring launches 01-11)
- Be Full: 110551
- He Empty: 111917
- He Full: 111884
TEMP: To Do
Experts should update the table as tasks are completed
Subdetector | Plots | Instructions | Expert(s) |
---|---|---|---|
BCAL | Confirm existing ones are relevant | Confirm existing ones are accurate | Mark Dalton, Zisis Papandreou, Igal Jaegle |
CCAL | Select relevant plots | Write instructions for volunteers | Drew Smith |
CDC | Confirm existing ones are relevant | Confirm existing ones are accurate | Naomi Jarvis |
FCAL | Confirm existing ones are relevant | Write instructions for volunteers | Mark Dalton, Malte Albrecht, Igal Jaegle |
FDC | Confirm existing ones are relevant | Write instructions for volunteers | Lubomir Pentchev |
PS | Confirm existing ones are relevant | Write instructions for volunteers | Alex Somov, Olga Cortes |
SC | Confirm existing ones are relevant | Write instructions for volunteers | Beni Zihlmann |
TAGH | Confirm existing ones are relevant | Write instructions for volunteers | Alex Somov, Bo Yu |
TAGM | Confirm existing ones are relevant | Write instructions for volunteers | Richard Jones, Ellie Prather |
TOF | Confirm existing ones are relevant | Write instructions for volunteers | Paul Eugenio, Beni Zihlmann |
RF | Confirm existing ones are relevant | Confirm existing ones are accurate | Sean Dobbs, Beni Zihlmann |
Timing | Confirm existing ones are relevant | Confirm existing ones are accurate | Sean Dobbs |
Analysis | Confirm existing ones are relevant | Confirm existing ones are accurate | Alex Austregesilo, Sean Dobbs |
BCAL
- Check Occupancy - Reference: [ link ]
- Check Hit Efficiency - Reference: [ link ]
- Check Recon. BCAL 1 - Reference: [ link ]
- Check Recon. BCAL 2 - Reference: [ link ]
- Check BCAL Matching - Reference: [ link ]
BCAL Reference Plots
BCAL Notes
CCAL
- List of plots to check goes here
CCAL Reference Plots
CCAL Notes
CDC
- Check Occupancy - Reference: [ link ]
- Check Time-to-distance - Reference: [ link ]
- Check dE/dx - Reference: [ link ]
- Check Efficiency - Reference: [ link ]
CDC Reference Plots
CDC Notes
FCAL
- Check Occupancy - Reference: [ link ]
- Check FCAL Hits 1 - Reference: [ link ]
- Check FCAL Hits 2 - Reference: [ link ]
- Check FCAL Clusters 1 - Reference: [ link ]
- Check FCAL Recon. 1 - Reference: [ link ]
- Check FCAL Recon. 2 - Reference: [ link ]
- Check Recon. FCAL Matching - Reference: [ link ]
FCAL Reference Plots
FCAL Notes
FDC
- Check Package 1 Occupancy - Reference: [ link ]
- Check Package 2 Occupancy - Reference: [ link ]
- Check Package 3 Occupancy - Reference: [ link ]
- Check Package 4 Occupancy - Reference: [ link ]
FDC Reference Plots
FDC Notes
PS
- Check Occupancy - Reference: [ link ]
- Check Timing Alignment - Reference: [ link ]
- Check PS Pair Energy - Reference: [ link ]
PS Reference Plots
PS Notes
SC
- Check Occupancy - Reference: [ link ]
- Check Recon. SC 1 - Reference: [ link ]
- Check Recon. SC 2 - Reference: [ link ]
- Check Recon. SC Matching - Reference: [ link ]
SC Reference Plots
SC Notes
TAGH
TAGH Reference Plots
TAGH Notes
TAGM
TAGM Reference Plots
TAGM Notes
TOF
- Check Occupancy - Reference: [ link ]
- Check TOF Matching 1 - Reference: [ link ]
- Check TOF Matching 2 - Reference: [ link ]
TOF Reference Plots
TOF Notes
RF
- Check Timing Offsets - Reference: [ link ]
RF Reference Plots
RF Instructions
Timing
- Check HLDT Calorimeter Timing - Reference: [ link ]
- Check HLDT Drift Chamber Timing - Reference: [ link ]
- Check HLDT PID System Timing - Reference: [ link ]
- Check HLDT Tagger Timing - Reference: [ link ]
- Check HLDT Tagger/RF Align 2 - Reference: [ link ]
- Check HLDT Tagger/SC Align - Reference: [ link ]
- Check HLDT Track-Matched Timing - Reference: [ link ]
Timing Reference Plots
Timing Notes
Analysis
- Tracking 1 - [ link ]
- Tracking 3 - [ link ]
- Check BCAL pi0 - Reference: [ link ]
- Check BCAL/FCAL pi0 - Reference: [ link ]
- Check p+2pi - Reference: [ link ]
- Check p+3pi - Reference: [ link ]
- Check p+pi0g - Reference: [ link ]
Analysis Reference Plots
Analysis Notes