Difference between revisions of "Start Counter Operations 2017"

From GlueXWiki
Jump to: navigation, search
(Created page with "=== Start Counter Performance 2017 === as of 2024:0921 the performance of the Start Counter can be interpreted by looking at the dEdx values shown in the SC deamon plot: Fi...")
 
(Start Counter Performance 2017)
Line 1: Line 1:
 
=== Start Counter Performance 2017 ===
 
=== Start Counter Performance 2017 ===
  
as of 2024:0921 the performance of the Start Counter can be interpreted by looking at the dEdx values shown in the SC deamon plot:
+
as of 2024:0921 the performance of the Start Counter can be interpreted by looking at the dEdx values shown in the SC deamon plot:<br>
[[File:sc_dedx_2017.png |300px]]
+
[[File:sc_dedx_2017.png |300px]]<br>
 +
from these data one can clearly identify periods where there are significant changes that can be tradced back to changes in the response of the detector and is real and not an artefact of the calibration. For example, it can be shown that the ADC amplitudes of all the 30 paddles in run 30858 are about 7.8% larger than for run 30900. This is a significant change/drop in the response of the detector. This drop seems to happen immediate. There is no change in the operating voltage observed. And while the temperature of the CDC gas and the HallD air temperature monitored and recored in EPICS data base show some wired jumps around that time, the temperature became stable again at more or less previous values but the reduced response of the start counter paddles at the level of 7.8% remained.

Revision as of 09:17, 21 September 2024

Start Counter Performance 2017

as of 2024:0921 the performance of the Start Counter can be interpreted by looking at the dEdx values shown in the SC deamon plot:
Sc dedx 2017.png
from these data one can clearly identify periods where there are significant changes that can be tradced back to changes in the response of the detector and is real and not an artefact of the calibration. For example, it can be shown that the ADC amplitudes of all the 30 paddles in run 30858 are about 7.8% larger than for run 30900. This is a significant change/drop in the response of the detector. This drop seems to happen immediate. There is no change in the operating voltage observed. And while the temperature of the CDC gas and the HallD air temperature monitored and recored in EPICS data base show some wired jumps around that time, the temperature became stable again at more or less previous values but the reduced response of the start counter paddles at the level of 7.8% remained.