Difference between revisions of "Configuration for 2025 run"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
  
* Connection of signal cables (D2-4-BOT, ccal crate)
+
All signal cables are connected to the flash ADC in Slot 3 of the D2-4-BOT, ccal crate.
 
+
The TAC is connected to the former CCAL crate. The reconstruction of TAC hits (and EPICS scalers) can be done using
All signal cables are connected to the flash ADC in Slot 3
+
the CCAL translation table.  The TAC HV is provided by the CAEN module in Slot 10 of the halldcaenhv10 (D2-8-MID, 129.57.26.211)
 +
crate. This crate also contains HV modules for the DIRC. The mapping of TAC channels is presented in the table below.
  
 
{|border="1" cellpadding="5" cellspacing="0" align="center"
 
{|border="1" cellpadding="5" cellspacing="0" align="center"
Line 57: Line 58:
  
  
The TAC HV is provided by the CAEN module in Slot 10 of the halldcaenhv10 (D2-8-MID, 129.57.26.211) crate. This crate also contains modules for the DIRC.
+
The definition of channels in the 3 x 3 PbWO4 array:
 +
 
 +
9 8 7
 +
6 5 4
 +
3 2 1

Revision as of 13:40, 6 March 2025

All signal cables are connected to the flash ADC in Slot 3 of the D2-4-BOT, ccal crate. The TAC is connected to the former CCAL crate. The reconstruction of TAC hits (and EPICS scalers) can be done using the CCAL translation table. The TAC HV is provided by the CAEN module in Slot 10 of the halldcaenhv10 (D2-8-MID, 129.57.26.211) crate. This crate also contains HV modules for the DIRC. The mapping of TAC channels is presented in the table below.

TAC channel ADC channel CCAL (column, row) HV channel (Slot 10, D2-8-MID)
1 0 1, 2 1
2 1 1, 3 2
3 2 1, 4 3
4 3 1, 5 4
5 4 2, 1 5
6 5 2, 2 6
7 6 2, 3 7
8 7 2, 4 8
9 8 2, 5 9


The definition of channels in the 3 x 3 PbWO4 array:

9 8 7 6 5 4 3 2 1