Difference between revisions of "Run Table"
From GlueXWiki
Line 6: | Line 6: | ||
3000 Sep24 13:40 5 Rotation ok ok ok ok 22537 2439 sample row | 3000 Sep24 13:40 5 Rotation ok ok ok ok 22537 2439 sample row | ||
− | 2314 | + | 2301 Sep23 11:11 ? 90deg, nominal height |
+ | 2306 Sep23 13:08 " | ||
+ | 2311 Sep23 16:11 " | ||
+ | 2312 Sep23 17:08 " | ||
+ | 2313 Sep23 18:16 " | ||
+ | 2314 Sep23 19:38 90deg (i.e.normal to beam) | ||
+ | 2315 Sep23 21:06 105deg | ||
+ | 2316 Sep23 21:51 119.5deg(max) | ||
+ | 2317 Sep23 23:08 115deg | ||
+ | |||
+ | 2318 Sep24 06:04(?!) 90deg, beam 3cm low (+3cm) | ||
+ | 2319 Sep24 02:12 +3cm | ||
+ | 2322 Sep24 04:46 +2cm | ||
+ | 2323 Sep24 06:46 +1cm | ||
+ | 2324 Sep24 09:10 -1cm | ||
+ | |||
</pre> | </pre> |
Revision as of 12:22, 24 September 2006
Click on the 'edit' tab above to record an entry in the table below.
<- BCAL -> Run No Date Time Curr. Config. Trigger Tagger ADC TDC Cell-3 Cell-8 Comments 3000 Sep24 13:40 5 Rotation ok ok ok ok 22537 2439 sample row 2301 Sep23 11:11 ? 90deg, nominal height 2306 Sep23 13:08 " 2311 Sep23 16:11 " 2312 Sep23 17:08 " 2313 Sep23 18:16 " 2314 Sep23 19:38 90deg (i.e.normal to beam) 2315 Sep23 21:06 105deg 2316 Sep23 21:51 119.5deg(max) 2317 Sep23 23:08 115deg 2318 Sep24 06:04(?!) 90deg, beam 3cm low (+3cm) 2319 Sep24 02:12 +3cm 2322 Sep24 04:46 +2cm 2323 Sep24 06:46 +1cm 2324 Sep24 09:10 -1cm
- Curr. refers to beam current.
- Configuration description options are shown below and are reflected in the Run Plan:
- Commissioning
- Rotation (platform, at 90 degrees, center of BCAL)
- Length (platform, at 90 degrees, length scan)
- Height (platform, at 90 degrees, up/down scan)
- Pre-radiator (platform, at 90 degrees, center of BCAL)
- Steep (alcove, at 10-50 degrees, at lengths intercepting full depth of BCAL)
- Leakage(alcove, at 10-25 degrees, at lengths allowing showers to leak out of end of BCAL)
- Current (platform, at 90 degrees, beam current study)
- Trigger (platform, at 90 degrees, trigger studies)
- Trigger, Tagger, BCAL-ADC, BCAL-TDC columns require checking ALL the spectra in the ROOT histos.
- The Cell columns reflect the number of counts/entries in the ANDed (North AND South) cell ADC spectrum. This provide a rough indication of hits on the particular cell.