Line 54: | Line 54: | ||
Energy (integrated amplitude) - new | Energy (integrated amplitude) - new | ||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
− | |width=" | + | |width="300pt"| |
− | [[Image:tilt_0_tracked_E_langaus_2.png|thumb| | + | [[Image:tilt_0_tracked_E_langaus_2.png|thumb|300px|Tracked energy (integrated amplitude); horizontal]] |
− | |width=" | + | |width="300pt"| |
− | [[Image:tilt_45_tracked_E_langaus_2.png|thumb| | + | [[Image:tilt_45_tracked_E_langaus_2.png|thumb|300px|Tracked energy (integrated amplitude); 45 degrees to horizontal]] |
+ | |width="300pt"| | ||
+ | [[Image:tilt_55_tracked_E_langaus_2.png|thumb|300px|Tracked energy (integrated amplitude); 55 degrees to horizontal]] | ||
|} | |} | ||
MPV: 3842/2220=1.73<br> | MPV: 3842/2220=1.73<br> |
Revision as of 16:30, 6 October 2010
Tracked cosmics with new preamp and HVB, 2050V, 50/50 premixed Ar/CO2.
Pink lines are Landau distributions, blue lines are Landau-Gaussian convolutions, fitted by ROOT.
Tilt angles are approx 45 and 55 degrees, vertical track length should increase x 1.4 and 1.74
Amplitude
Means: 452/311=1.45
MPV: 298/181=1.65
Amplitude - new
Means: 460/314=1.46 568/314=1.81
MPV: 283/182=1.55 371/182=2.0
Amplitude/ track-length
Amplitude/ track-length - new
Energy (integrated amplitude)
Energy (integrated amplitude) - new
MPV: 3842/2220=1.73
Energy (integrated amplitude)/ track-length
Energy (integrated amplitude)/ track-length - new
MPV: 293/170=1.72