Difference between revisions of "Event pics"

From GlueXWiki
Jump to: navigation, search
Line 8: Line 8:
  
  
55Fe events at 40 sccm total, 1850V (left) and 2050V (right)
+
55Fe events at 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
 
|width="400pt"|
 
|width="400pt"|
Line 14: Line 14:
 
|width="400pt"|
 
|width="400pt"|
 
[[Image:events_40_2050.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2050V]]
 
[[Image:events_40_2050.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2050V]]
 +
|width="400pt"|
 +
[[Image:events_40_2000.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2000V]]
 
|}
 
|}
  
Line 44: Line 46:
 
|}
 
|}
  
55Fe events, 40 sccm total, 1850V (left) and 2050V (right) The little blip at ~ch 250 in the RH plot is an afterpulse, this is not noticeable at 2000V.
+
55Fe events, 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).
 +
<br>The little blip at ~ch 250 in the RH plot is an afterpulse, this is not so noticeable at 2000V.
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
 
|width="400pt"|
 
|width="400pt"|
Line 50: Line 53:
 
|width="400pt"|
 
|width="400pt"|
 
[[Image:events_40_2050z.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2050V]]
 
[[Image:events_40_2050z.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2050V]]
 +
|width="400pt"|
 +
[[Image:events_40_2000z.png|thumb|400px|ADC contents for accumulated events:  55Fe mixed 50/50 at 2000V]]
 
|}
 
|}
  

Revision as of 10:31, 8 November 2010

55Fe events at 80 sccm total, 1850V (left) and 2050V (right)

ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V


55Fe events at 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).

ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2000V

The above are shown again lower down with the y-axis expanded around the pedestal.


Cosmics - events at 80 sccm total, 1850V (left) and 2050V (right)

ADC contents for accumulated events: cosmics mixed 50/50 at 1850V
ADC contents for accumulated events: cosmics mixed 50/50 at 2050V


Laser pollution and Cosmics - events at 40 sccm total, 2050V

ADC contents for accumulated events: cosmics mixed 50/50 at 2050V


55Fe events, zoomed in on pedestal... 80 sccm total, 1850V (left) and 2050V (right)

ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V

55Fe events, 40 sccm total, 1850V (left) and 2050V (right); 2000V (far right).
The little blip at ~ch 250 in the RH plot is an afterpulse, this is not so noticeable at 2000V.

ADC contents for accumulated events: 55Fe mixed 50/50 at 1850V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2050V
ADC contents for accumulated events: 55Fe mixed 50/50 at 2000V


Cosmics, zoomed in on pedestal - events at 80 sccm total, 1850V (left) and 2050V (right)

ADC contents for accumulated events: cosmics mixed 50/50 at 1850V
ADC contents for accumulated events: cosmics mixed 50/50 at 2050V