Difference between revisions of "Mattione Update 11162011"
From GlueXWiki
Line 1: | Line 1: | ||
+ | == Notes == | ||
+ | * CDC & FDC treated separately since they have different gas mixtures. | ||
+ | * Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored. | ||
+ | ** Truncates Landau distribution to resemble Gaussian distribution. | ||
+ | |||
+ | == CDC π<sup>+</sup>== | ||
+ | * Generated up to p = 2.0 GeV/c | ||
+ | |||
+ | * CDC π<sup>+</sup> dE/dx Mean, Resolution vs. βγ | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_11162011_MeandEdxVsBetaGamma_CDCPiPlus.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | ||
+ | | [[Image:Mattione_Update_11162011_SigmadEdxVsBetaGamma_CDCPiPlus.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | * CDC π<sup>+</sup> dE/dx Mean, Resolution in different dx Bins vs. βγ | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_11162011_MeandEdxVsBetaGammadxBins_CDCPiPlus.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | ||
+ | | [[Image:Mattione_Update_11162011_SigmadEdxVsBetaGammadxBins_CDCPiPlus.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
== FDC π<sup>+</sup> == | == FDC π<sup>+</sup> == | ||
* Generated up to p = 2.0 GeV/c | * Generated up to p = 2.0 GeV/c | ||
Line 20: | Line 42: | ||
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
− | == CDC π<sup>+</sup>== | + | == CDC vs. FDC π<sup>+</sup> == |
− | + | ||
− | * CDC π<sup>+</sup> dE/dx Mean, Resolution vs. βγ | + | * CDC vs. FDC π<sup>+</sup> dE/dx Mean, Resolution vs. βγ |
{| class="wikitable" | {| class="wikitable" | ||
− | | [[Image: | + | | [[Image:Mattione_Update_11162011_MeandEdxVsBetaGamma_CDCvsFDCPiPlus.gif|thumb|left|600px|π<sup>+</sup>]] |
− | | [[Image: | + | | [[Image:Mattione_Update_11162011_SigmadEdxVsBetaGamma_CDCvsFDCPiPlus.gif|thumb|left|600px|π<sup>+</sup>]] |
|} | |} | ||
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
− | * CDC π<sup>+</sup> dE/dx Mean, Resolution in different dx Bins vs. βγ | + | * CDC vs. FDC π<sup>+</sup> dE/dx Mean, Resolution in different dx Bins vs. βγ |
{| class="wikitable" | {| class="wikitable" | ||
− | | [[Image: | + | | [[Image:Mattione_Update_11162011_MeandEdxVsBetaGammadxBins_CDCvsFDCPiPlus.gif|thumb|left|600px|π<sup>+</sup>]] |
− | | [[Image: | + | | [[Image:Mattione_Update_11162011_SigmadEdxVsBetaGammadxBins_CDCvsFDCPiPlus.gif|thumb|left|600px|π<sup>+</sup>]] |
|} | |} | ||
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
− | |||
− |
Revision as of 21:18, 15 November 2011
Contents
Notes
- CDC & FDC treated separately since they have different gas mixtures.
- Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored.
- Truncates Landau distribution to resemble Gaussian distribution.
CDC π+
- Generated up to p = 2.0 GeV/c
- CDC π+ dE/dx Mean, Resolution vs. βγ
- CDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
FDC π+
- Generated up to p = 2.0 GeV/c
- FDC π+ dE/dx vs. βγ
- FDC π+ dE/dx Mean, Resolution vs. βγ
- FDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
CDC vs. FDC π+
- CDC vs. FDC π+ dE/dx Mean, Resolution vs. βγ
- CDC vs. FDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ