Difference between revisions of "Mattione Update 11162011"
From GlueXWiki
Line 1: | Line 1: | ||
− | == | + | == Introduction == |
− | * | + | * DC dE/dx information used for PID is bad, is disabled until fixed. |
− | + | ||
− | + | ||
− | + | ||
* DC dE/dx Confidence Level (for protons, similar for K+'s, π<sup>+</sup>'s, and π<sup>-</sup>). | * DC dE/dx Confidence Level (for protons, similar for K+'s, π<sup>+</sup>'s, and π<sup>-</sup>). | ||
[[Image:Mattione_Update_11162011_DCdEdxConfidenceLevel.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | [[Image:Mattione_Update_11162011_DCdEdxConfidenceLevel.gif|thumb|left|600px|CDC, π<sup>+</sup>]] | ||
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
+ | |||
+ | === Notes === | ||
+ | * CDC & FDC treated separately since they have different gas mixtures. | ||
+ | * Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored. | ||
+ | ** Truncates Landau distribution to resemble Gaussian distribution. | ||
== CDC π<sup>+</sup>== | == CDC π<sup>+</sup>== |
Revision as of 11:36, 16 November 2011
Introduction
- DC dE/dx information used for PID is bad, is disabled until fixed.
- DC dE/dx Confidence Level (for protons, similar for K+'s, π+'s, and π-).
Notes
- CDC & FDC treated separately since they have different gas mixtures.
- Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored.
- Truncates Landau distribution to resemble Gaussian distribution.
CDC π+
- Generated up to p = 2.0 GeV/c
- CDC π+ dE/dx Mean, Resolution vs. βγ
- CDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
FDC π+
- Generated up to p = 2.0 GeV/c
- FDC π+ dE/dx vs. βγ
- FDC π+ dE/dx Mean, Resolution vs. βγ
- FDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
CDC vs. FDC π+
- CDC vs. FDC π+ dE/dx Mean, Resolution vs. βγ