Line 10: | Line 10: | ||
!width="50" | Number of Addresses | !width="50" | Number of Addresses | ||
!width="200" | Broadcast Address | !width="200" | Broadcast Address | ||
+ | |- | ||
+ | | DAQ || 129.57.135.0/24 || VLAN 635 ? || 256 || 129.57.135.255 | ||
|- | |- | ||
| Controls || 129.57.26.0/23 || VLAN 526 || 512 || 129.57.27.255 | | Controls || 129.57.26.0/23 || VLAN 526 || 512 || 129.57.27.255 | ||
|- | |- | ||
− | | | + | | General || 129.57.172.0/22 || VLAN 672 || 1024 || 129.57.175.255 |
|- | |- | ||
| Development || 129.57.194.0/24 || VLAN 694 || 256 || 129.57.194.255 | | Development || 129.57.194.0/24 || VLAN 694 || 256 || 129.57.194.255 |
Revision as of 09:42, 13 August 2013
This page provides the information on conventions on IP name and address on the devices routed off the Hall D main Cisco router.
Contents
Hall D Internal Networks
Purpose | Network | VLAN | Number of Addresses | Broadcast Address |
---|---|---|---|---|
DAQ | 129.57.135.0/24 | VLAN 635 ? | 256 | 129.57.135.255 |
Controls | 129.57.26.0/23 | VLAN 526 | 512 | 129.57.27.255 |
General | 129.57.172.0/22 | VLAN 672 | 1024 | 129.57.175.255 |
Development | 129.57.194.0/24 | VLAN 694 | 256 | 129.57.194.255 |
Infiniband | 172.19.5.0/24 | Local | 256 | 172.19.5.255 |
IP Name Conventions
Desktop Computers and Servers
- Use gluonxx.jlab.org for the online servers main IP addresses. The name comes from GLUex ONline abbreviation.
- If we want to keep the same name for Lelvel 3 farm servers, then we will need to use gluonxxx.jlab.org.
- The additional Ethernet ports will be labeled gluonxx_y.jlab.org for servers with multiple interfaces.
- We can divide the numbers into ranges for different types of servers, see the table below.
- Note that Level3 is the only one with three digits after "gluon"
Type | Name Range |
---|---|
Desktops | gluon00 - gluon19 |
General Purpose Servers | gluon20 - gluon39 |
EMU | gluon40 - gluon59 |
Level3 | gluon100 - gluon999 |
Controllers and fan trays for VXS/VME crates
- Use "rocname" for interface 0 which will be used by the fast DAQ. For instance rocfdc1
- For controls and monitoring we can use interface 1 on the controller called "iocname". For instance, iocfdc1 .
- For the fan trays we can use "vmename". For instance, vmefdc1 .
Embedded devices
- Continue notation "hallddevice", where device is the name that describes the device type and the number of that device. For instance, hallden2t2.jlab.org or halldbrooks1.jlab.org. Or for High Voltage and Low Voltage devices halldcaen1, halldmpod1, halldcan1. For the main file server we can use halldfs1, and for fast the RAID file servers we can use halldraid1, halldraid2.
Crate Names
- Each major detector component will have a number of crates named based on its GlueX name, followed by one or two digits specifying the number of the crate.
- If more than one detector component is a part of one crate only one name is assigned, preferably of the larger one or a name that can characterize both detectors, e.g. use "tagx" for TAGM&TAGH crates.
- Numbering assignment with respect to the geographical location (the map) will need to be created out before requesting IP names. The map should define one-to-one corresponds between this detector-based scheme and one based on the geographical location ordering of the crates in the racks and the Hall.
- The VME crates with the JLab discriminators are separated from the other VXS crates, they are considered as a separate "detector" for the naming purposes.
Detector | Crate Names | Possible modules |
---|---|---|
TAGM/TAGH | tag1 - tag3 | fADC250/F1TDC |
PS/PSC | ps1 - ps2 | fADC250/F1TDC |
ST | st1 - st2 | fADC250/F1TDC |
TRIG | trig1 - trig2 | GTP/TS/TD |
BCAL | bcal1 - bcal12 | fADC250/F1TDC |
CDC | cdc1 - cdc4 | fADC125 |
FDC | fdc1 - fdc14 | fADC125/F1TDC |
TOF | tof1 - tof2 | fADC250/CAEN TDC |
FCAL | fcal1 -fcal12 | fADC250 |
DISC | dscr1 -dscr8 | JLab Discriminators |