Difference between revisions of "Level-3 Trigger Strategy"
From GlueXWiki
Line 9: | Line 9: | ||
! !! Phase I !! Phase II !! Phase III !! Phase IV | ! !! Phase I !! Phase II !! Phase III !! Phase IV | ||
|- | |- | ||
− | | PAC days || | + | | PAC days || 30 || 30 || 60 || 200 |
|- | |- | ||
− | | Minimum electron energy (GeV) || | + | | Minimum electron energy (GeV) || 10 || 11 || 12 || 12 |
|- | |- | ||
− | | Photon flux in coherent peak (photon/s) || | + | | Photon flux in coherent peak (photon/s) || <math>10^6</math> || <math>10^7</math> || <math>10^7</math> || <math>5 \times 10^7</math> |
|- | |- | ||
− | | Level-1 trigger rate (kHz) | + | | Level-1 trigger rate (kHz) || 2 || 20 || 20 || 200 |
|} | |} |
Revision as of 09:15, 19 August 2013
Contents
This page will collect the current planned running times/intensities for GlueX and the expected event rates. Based on this a set of requirements can be collected for the Level-3 trigger to document the strategy for implementation
Approved GlueX Running Time
Phase I | Phase II | Phase III | Phase IV | |
---|---|---|---|---|
PAC days | 30 | 30 | 60 | 200 |
Minimum electron energy (GeV) | 10 | 11 | 12 | 12 |
Photon flux in coherent peak (photon/s) | ||||
Level-1 trigger rate (kHz) | 2 | 20 | 20 | 200 |