Difference between revisions of "Feb 4, 2015 BCAL Commissioning"
From GlueXWiki
(→Tentative Agenda) |
(→Tentative Agenda) |
||
Line 32: | Line 32: | ||
#* Verify fixes with LED runs | #* Verify fixes with LED runs | ||
#* Humidity settings | #* Humidity settings | ||
+ | #* Attempt +5 C? | ||
#* Check channel efficiencies | #* Check channel efficiencies | ||
#* Verify pi0 statistics, estimate amount required | #* Verify pi0 statistics, estimate amount required | ||
Line 47: | Line 48: | ||
#* Automate and enhance scripts to analyze the pulser runs. | #* Automate and enhance scripts to analyze the pulser runs. | ||
# Cosmic-Ray runs | # Cosmic-Ray runs | ||
+ | #* Settings for cosmic runs: shall we match settings for April running? | ||
#* Can we check efficiencies for a given DAQ threshold? | #* Can we check efficiencies for a given DAQ threshold? | ||
#* How to effectively use data triggered on the BCAL? | #* How to effectively use data triggered on the BCAL? |
Revision as of 15:10, 4 February 2015
Contents
Video Conferencing Information
Meeting Time: 3:00 p.m. Eastern
- To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
- To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
- To join via phone, use one of the following numbers and the Conference ID: 907185247.
- US or Canada: +1 408 740 7256 or
- US or Canada: +1 888 240 2560
- Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
- More information on connecting to bluejeans is available.
Participant Direct Lines
- JLab Phone: in CC F326 is 757-269-6460 (usual room)
- JLab Phone in CC L207 is 757-269-7084
- Phone in the Regina Video-conference Suite is 306-585-4204
- Athens Phone: in Christina's office is 011-30-210-727-6947
Resources
Action Items
Tentative Agenda
- Announcements
- Action Items
- What do we need to do before the spring run?
- Verify fixes with LED runs
- Humidity settings
- Attempt +5 C?
- Check channel efficiencies
- Verify pi0 statistics, estimate amount required
- Parameters
- DAQ thresholds
- Bias voltage setting
- N_sa and N_sb
- Effective velocity
- Time offsets
- Time-walk corrections
- LED pulser runs
- Verify fixes to hardware channels
- Check humidity readback/settings
- Create configuration that takes data through the TS for concurrent north and south running
- Automate and enhance scripts to analyze the pulser runs.
- Cosmic-Ray runs
- Settings for cosmic runs: shall we match settings for April running?
- Can we check efficiencies for a given DAQ threshold?
- How to effectively use data triggered on the BCAL?
- How to calibrate timing?
- What simulations are needed to support all calibration?
- Any other business
Minutes
Attendees: