+ | =Final States Used For Calibrations= | ||
+ | |||
+ | This is a partial list of final states that can be used for calibrations. Fully reconstructed reactions give clean inputs to calibrations procedures. It would be helpful to have rate/efficiency studies for these reactions. | ||
+ | |||
+ | * p γ → p π<sup>0</sup> | ||
+ | * p γ → p η ; η → γ γ | ||
+ | * p γ → p ω ; ω → γ π<sup>0</sup> | ||
+ | * p γ → p ω ; ω → π<sup>+</sup> π<sup>-</sup> π<sup>0</sup> | ||
+ | * p γ → p φ ; φ → K<sup>+</sup> K<sup>-</sup> | ||
+ | * p γ → p K<sub>S</sub> + X | ||
+ | * p γ → Λ K<sup>+</sup> ; Λ → p π<sup>-</sup> | ||
=Fall 2015= | =Fall 2015= |
Revision as of 17:04, 20 October 2015
Contents
Final States Used For Calibrations
This is a partial list of final states that can be used for calibrations. Fully reconstructed reactions give clean inputs to calibrations procedures. It would be helpful to have rate/efficiency studies for these reactions.
- p γ → p π0
- p γ → p η ; η → γ γ
- p γ → p ω ; ω → γ π0
- p γ → p ω ; ω → π+ π- π0
- p γ → p φ ; φ → K+ K-
- p γ → p KS + X
- p γ → Λ K+ ; Λ → p π-
Fall 2015
Calibration data needs as of Oct. 6, 2015
Detector | Status | Data in Hand | Est. Data Needed | Est. Running Time | Notes |
---|---|---|---|---|---|
BCAL | More Needed | 130k pi0 | 25-50x | ~43 - 85 hr | pi0 cluster energy > 750 MeV |
CDC | OK | 350 M cosmics | |||
FCAL | More Needed | 125k pi0 | 10x | ~1 - 2 hr | pi0 cluster energy > 1 GeV |
FDC | OK | 3 shifts, 10^-4 radiator, 100 nA, no field needed | |||
PS/PSC | OK | ||||
Start Counter | More Needed | 80 M tracks | 10x | ~4 hr | basic calibrations are good, more refinement possible |
TAGH | OK | ||||
TAGM | More Needed | 10 M - 50 M | 4 hr | ||
TOF | OK | need to verify stability of calibrations with more data |
Projected running times scaled up from conditions in Run 3185. Assumes 12 GeV e- beam with 100 nA current.
Notes
- Data needed depends strongly on S/B, especially for calorimeters.
- Lowering thresholds can have a large effect, too
- SC run list: 2931, 2932, 2933, 2934
- BCAL/FCAL run list: 2931, 3185 [diamond]; 3079, 3179, 3180, 3182, 3199, 3200, 3201, 3217 [1x10-4 RL amorphous]
- Scaling factor: diamond = 8 x amorphous
- CDC/FDC will need more data to calibrate fADC125 algorithm when it's deployed.
Scaling from 6 GeV to 12 GeV
- 6 GeV settings: 5.5 GeV e- beam, 50 um diamond radiator, 5 mm collimator, E(gam) = 2 - 5.5 GeV
- 12 GeV settings: 12 GeV e- beam, 20 um diamond radiator, 3.4 mm collimator, E(gam) = 7 - 12 GeV
- rate(12 GeV) / rate(6 GeV) ~ 80% [using cobrems in bggen, incl. plastic target on nose removal in 12 GeV era].
- Geometrical factors: (12 GeV/6 GeV)
- SC - ~1x (straight section drives needs)
- BCAL - ~1x (both photons in BCAL)
- FCAL - ~8x (both photons in FCAL)
Runs
Run | Events | Run Time (hr) | Evts/hr |
---|---|---|---|
3185 | 19.9 M | 2.2 | 9.0 M |
2931 | 74.6 M | 7.4 | 10.1 M |
2932 | 0.4 M | 0.1 | 4.0 M |
2933 | 3.0 M | 0.7 | 4.3 M |
2934 | 3.6 M | 1.5 | 2.4 M |
3079 | 25.9 M | 7.0 | 3.7 M |
3179 | 14.6 M | 1.75 | 8.3 M |
3180 | 41.3 M | 4.8 | 8.6 M |
3199 | 4.4 M | 3.0 | 1.5 M |
3200 | 12.5 M | 9.0 | 1.4 M |
3201 | 5.6 M | 5.4 | 1.0 M |