Difference between revisions of "Scaler Data Format"
From GlueXWiki
Line 36: | Line 36: | ||
* Live time | * Live time | ||
* Busy time | * Busy time | ||
− | * Instantaneous | + | * Instantaneous live time |
− | + | * Unix time | |
− | + | ||
− | + | ||
− | + | * GTP scalers, line 0 - 31 | |
− | + | * FP scalers, line 0 - 16 | |
− | + | * GTP rate, line 0 - 31 | |
+ | * FP rate, line 0 - 16 |
Latest revision as of 12:53, 14 June 2016
FADC250 scalers
Bank EE10 (Df250Scaler)
- Number of sync events
- Trigger number
- Format version number
- Crate
(vector of 32-bit words)
- slot
- 16 fadc rates
FADC250 Asynchronous pedestals
Bank EE05 (Df250AsyncPedestal)
- Number of sync events
- Trigger number
- Crate
(vector of 32-bit words)
- slot
- 16 fadc rates
TS/GTP scalers
Bank EE02 (DL1Info)
- Number of sync events
- Trigger number
- Live time
- Busy time
- Instantaneous live time
- Unix time
- GTP scalers, line 0 - 31
- FP scalers, line 0 - 16
- GTP rate, line 0 - 31
- FP rate, line 0 - 16