Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
(→Occupancy of the Issue) |
(→Occupancy of the Issue) |
||
Line 16: | Line 16: | ||
! log post | ! log post | ||
|- | |- | ||
− | ! scope=row | | + | ! scope=row | 2020 Jan 27, 15:18 |
− | | | + | | Yes |
− | | | + | | https://logbooks.jlab.org/entry/3772139 |
|- | |- | ||
! scope=row | Row header A | ! scope=row | Row header A |
Revision as of 12:40, 28 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue
Date | Resolved after DAQ reboot | log post |
---|---|---|
2020 Jan 27, 15:18 | Yes | https://logbooks.jlab.org/entry/3772139 |
Row header A | Cell B | Cell C |