Difference between revisions of "PMT tiles missing after restarting data taking"
From GlueXWiki
(→Occupancy of the Issue) |
(→Occupancy of the Issue) |
||
Line 13: | Line 13: | ||
{| class="wikitable" | {| class="wikitable" | ||
! Date | ! Date | ||
− | ! | + | ! Resolved After DAQ Reboot |
! Box Tile | ! Box Tile | ||
! Log Post | ! Log Post |
Revision as of 12:46, 28 January 2020
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right).
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue
Date | Resolved After DAQ Reboot | Box Tile | Log Post |
---|---|---|---|
2020 Jan 27, 15:18 | Yes | North c1 r15 | https://logbooks.jlab.org/entry/3772139 |