All public logs
From GlueXWiki
Combined display of all available logs of GlueXWiki. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)- 09:14, 26 August 2008 Zihlmann (Talk | contribs) uploaded File:Kuraray 81MC sr 165cm.gif (XP2020 response on the electrons from a Sr90 source positioned on top of the 81MC blue fiber from Kuraray at 165cm.)
- 09:13, 26 August 2008 Zihlmann (Talk | contribs) uploaded File:Kuraray 81MC sr 65cm.gif (XP2020 response on the electrons from a Sr90 source positioned on top of the 81MC blue fiber from Kuraray at 65cm. )
- 18:17, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Trigger scintillator response.gif (ADC spectrum of the Trigger scintillator. The PMT is a Hamamatsu H3165-10 PMT with a small scintillator attached.)
- 18:11, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Xp2020 led response 2200V B.gif (ADC spectrum of xp2020 at -2200V response to blue LED biased at -7.90V. mu is the mean number of photo electrons given by the fit to be about 2.5)
- 18:09, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Xp2020 led response 2200V A.gif (ADC spectrum of the xp2020 PMT response to a blue LED biased with -7.89V)
- 10:24, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Sr source.jpg (Sr90 source placed above collimator with scintillation fiber and trigger scintillator detector below.)
- 10:23, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Collimation.jpg (collimation of electrons from Sr90 source. Trigger scintillator is below.)
- 10:22, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Fiber coupling.jpg
- 09:02, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Fiber test stand darkbox.jpg
- 08:44, 25 August 2008 Zihlmann (Talk | contribs) uploaded File:Fiber test electronics setup.pdf (sketch of the NIM electronics for the fiber test at JLAB)
- 19:00, 21 August 2008 Zihlmann (Talk | contribs) uploaded File:Fine mesh pmt test overview.pdf (short over view of the fine mesh pmt test done in Hall-A in the gap of Big-Bite)
- 10:31, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Cdc closedpacking.jpg (The closed packing allows for 3 more layers for the same CDC diameter. These layers are set as stereo layers set at +6 degree as the outermost layers of the CDC.)
- 10:27, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Cdc closedpacking zoom.jpg (centeral view of CDC (z=0) cross section with close-packing of axial layers. all axial layers come in pairs.)
- 10:24, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Cdc layers shifted.jpg (view of the CDC at the center (z=0) with axial layers rotated around z axis to avoid lineup of straws.)
- 10:17, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal 3x3.jpg (The BCAL 3x3 inner readout scheem)
- 10:16, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal 6x4.jpg (BCAL wedge with 6x4 inner readout scheem and aluminum plate on the inside.)
- 10:12, 17 July 2008 Zihlmann (Talk | contribs) uploaded File:Fdc cableupstream.jpg (FDC package geometry with first lowest layer cables of FDC1 package running upstream)
- 18:52, 2 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal cdc gap.pdf (gap between CDC and BCAL for cables from FDCs)
- 18:52, 2 July 2008 Zihlmann (Talk | contribs) uploaded File:Det cabling.pdf (geometry file, implementation of BCAL, CDC and FDC cables)
- 18:51, 2 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal 3x3.pdf (geometry file, implementation of 3x3 Bcal inner readout )
- 18:50, 2 July 2008 Zihlmann (Talk | contribs) uploaded File:Bcal 4x6.pdf (geometry file, implemenation of BCAL 4x6 inner readout)
- 14:55, 5 June 2008 Zihlmann (Talk | contribs) uploaded File:Gxroot.pdf (how to use the root geometry in DANA)
- 17:35, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu noise cwbase bestbase lowestnoise.jpg (CW-base with very low noise. Lowest noise of all bases that were looked at.)
- 15:09, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu noise cwbase.jpg (Signal and noise (scope shot) from one of the PMTs during the test to measure the temperature of the CW-Bases mounted in the platic block. The noise is from the base itself.)
- 15:06, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Feu signalB cwbase.jpg (Signal (cope shot) from one of the four PMTs when testing the temperature of the CW-base mounted in the plastic block.)
- 14:42, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Cosmics response LGwrapped.jpg (ADC spectrum of cosmic ray data. The PMT is coupled to the lead glass through a 3.7cm long light guide that was glued to the PMT with epoxy and attached to the lead glass with optical grease. The light guide is wrapped in aluminized mylar.)
- 14:40, 5 February 2008 Zihlmann (Talk | contribs) uploaded File:Cosmics response airgap.jpg
- 14:51, 29 January 2008 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 atten bothpmts.jpg
- 19:50, 24 January 2008 Zihlmann (Talk | contribs) uploaded File:Tofres 550cm tof.jpg
- 11:02, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Surfaces.jpg (ligh guide test with mirroring the surface using aluminum vapor or just aluminized mylar.)
- 10:48, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 atten pmt2.jpg (plot the ADC landau peak position (MPV) from the fit as a function of the position of the sctintillator trigger along the lead glass block. Then fit an exponential function of the form f(x)=a+exp(x/b) where b is the attenuation factor.)
- 10:44, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Leadglass F8 velo pmt2.jpg (plot the TOF peak position as function of the cosmic ray trigger sctintillator position and fit a line to the points. The inverse of the slope is proportional to the signal propagation velocity in the lead glass.)
- 10:42, 14 November 2007 Zihlmann (Talk | contribs) uploaded File:Lg adcR center.jpg (ADC spectrum of PMT response with the cosmic trigger sctintillators positioned at the center of the lead glass block. The fit is a landau convoluted with a gaussian. The PMT used are XP2262.)
- 13:49, 9 November 2007 Zihlmann (Talk | contribs) uploaded File:Lead glass refrac index.jpg (lead glass refractive index for type F1 and F8 as function of wavelength)
- 13:47, 9 November 2007 Zihlmann (Talk | contribs) uploaded File:Lead glass transmission.jpg (light transmission in lead glass type F1 and F8 as function of wavelength)
- 14:24, 1 November 2007 Zihlmann (Talk | contribs) uploaded File:Qe feu843.jpg (quantum efficiency for FEU-84-3 PMT)
- 16:33, 30 October 2007 Zihlmann (Talk | contribs) uploaded File:Raddam.jpg (lead glass transparency dependence on wavelength)
- 13:39, 1 October 2007 Zihlmann (Talk | contribs) moved page GlueXWiki:Help to PMT FEU-84-3
- 14:00, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 1.jpg
- 13:43, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 2b.jpg
- 13:42, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 2a.jpg
- 13:41, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Part mult vs angl 1a.jpg (Angular distribution of low momentrum particles geneated by pythia)
- 13:39, 10 September 2007 Zihlmann (Talk | contribs) uploaded File:Pythia lowp angular dist1.jpg (Angular distrubion of low momentum particles generated in pythia)
- 09:28, 24 July 2007 Zihlmann (Talk | contribs) uploaded File:Tofstat.pdf
- 09:28, 24 July 2007 Zihlmann (Talk | contribs) uploaded File:Tofstatus.pdf
- 17:33, 23 July 2007 Zihlmann (Talk | contribs) uploaded File:Tofstat.pdf
- 17:29, 23 July 2007 Zihlmann (Talk | contribs) uploaded File:Tofstat.pdf
- 17:26, 23 July 2007 Zihlmann (Talk | contribs) uploaded File:Tofstatus.pdf
- 11:55, 17 July 2007 Zihlmann (Talk | contribs) uploaded File:Flowchart.pdf
- 18:26, 25 June 2007 Zihlmann (Talk | contribs) uploaded File:Tofdigi1.pdf (TOF digitizatino status June 26 2007)