Specification for the two-dipole tagging spectrometer
From GlueXWiki
Global Tagging Spectrometer Specification
Main beam momentum | 12 GeV/c |
Momenum range of analyzed electrons | 0.5 to 9 GeV/c |
Main beam radius | 26.685 m |
Main beam bending angle | 13.4° |
Entrance face angle for the first magnet | 5.9° |
Magnetic field (full excitation) | 15.0000 kG |
Pole gap | 30 mm |
Tagger Dipoles
Length | 3.09 m |
Width | 1.09 m |
Height | 1.41 m |
Weight | 38 Mg |
Separation between magnets | 40 cm |
Angle between magnets | 0.892° |