Mattione Update 04042012
From GlueXWiki
TOF
- VERY FEW hits reconstructed in TOF.
- TOF reconstruction (DTOFHit factory) requires hits in both the "North" and "South" PMTs of a scintillator to be > 1 MeV.
- TOF Hit North Energy vs. p (Reconstruction energy threshold cut at 1 MeV)
- TOF Hit South Energy vs. p (Reconstruction energy threshold cut at 1 MeV)
FCAL
- Δβ (βt - βp) vs. p
- Δβ offset is accounted for by time offset below.
- Δt (treconstructed - ttrue) vs. p
BCAL
- Δβ (βt - βp) vs. p
- Δt & Δp are OK, it looks like the problem is with the start time (at least for the pions) (set to weighted average of start counter hit times instead of RF bunch times).
- Δt (treconstructed - ttrue) vs. p