PMT tiles missing after restarting data taking
From GlueXWiki
Revision as of 14:08, 28 January 2020 by Billlee (Talk | contribs) (→Occupancy of the Issue During Operation)
Description on the Symptoms
After restarting DAQ, the missing tiles can be seen on the occupancy plots on Rootspy (see an example image to the right). The same missing tile can be observed on the 2D scalar screen too.
Solution
- Stop the current run.
- Completely restart Coda (by pressing STOP button on the RCM GUI).
- Start Coda normally (Configure->Download->Prestart->Start)
- Call DIRC expert if problem was not resolved.
Occupancy of the Issue During Operation
Date | Resolved After DAQ Reboot | Box Tile | Run Effected | Log Entry |
---|---|---|---|---|
2020 Jan 27, 15:18 | Yes | North c2:r15 | 71595 | https://logbooks.jlab.org/entry/3772139 |
2020 Jan 15, 13:43 | Yes | South c2:r7 | 71397 | https://logbooks.jlab.org/entry/3764225 |
2020 Jan 12, 06:32 | Yes | North c2:r4 | 71367 | https://logbooks.jlab.org/entry/3762186 |