New fADC with cosmics

From GlueXWiki
Revision as of 15:47, 11 April 2011 by Nsjarvis (Talk | contribs)

Jump to: navigation, search
  • 50/50 mixed Ar, CO2
  • Recalibrated MFCs
  • Outer plenum added to CDC prototype to prevent leaks
  • New preamp
  • New HVB

Cosmics, 2050V, max amplitude histograms, new fADC with unmodified HVB (left), with modified HVB (center) and Struck fADCs with modified HVB (right), same straw for each.
NB different x axis scale, full scale is 4096 for both ADCs.

Max amplitude histo for cosmics, new fADC, unmodified HVB, mixed 50/50 at 60 sccm 2050V
Max amplitude histo for cosmics, new fADC, modified HVB, mixed 50/50 at 60 sccm 2050V
Max amplitude histo for cosmics, Struck fADCs, modified HVB, mixed 50/50 at 60 sccm, 2050V


Cosmics, 2050V, drift time - untracked, new fADC (left) and Struck fADCs (right), same straw for both.


New fADC cosmics drift time (untracked), mixed 50/50 at 60 sccm 2050V
Struck fADCs cosmics drift time (untracked), mixed 50/50 at 60 sccm, 2050V

Cosmics, 2050V, drift radius fit residuals (radius of fitted track - radius interpolated from Garfield drift time calcs)
New fADC with unmodified HVB (left), with modified HVB (center) and Struck fADCs with modified HVB (right), same straw for each.

Drift radius fit residuals, new fADC, unmodified HVB, mixed 50/50 at 60 sccm 2050V
Drift radius fit residuals, new fADC, modified HVB, mixed 50/50 at 60 sccm 2050V
Drift radius fit residuals, Struck fADCs, modified HVB, mixed 50/50 at 60 sccm, 2050V