July 31, 2013 Tracking CDC/FDC
From GlueXWiki
Meeting Time and Place
Wednesday July 31, 2013 at 11:00am At Jefferson Lab, the meeting will be held in F326
Connections
To connect from the outside, please use ESNET
- ) ESNET: 8542553
- )To connect by telephone, dial:
- You can look up toll-free number at http://www.readytalk.com/intl
- US and Canada: (866)740-1260 (toll free)
- International: (303)248-0285 (toll call)
- enter access code followed by the # sign: 3421244#
Hardware Agenda
- Announcement
- FDC Update
- CDC Update
- Data Formats
Minutes
Present: Naomi, Beni, Simon, David, Cody
- FDC Update
- CDC Update
- We are now reading out data from all 3 new fadcs, data look fine, tracks aplenty.
- Data Formats
- fADC125 Data Format Document
- We decided to reinstate data type 5 (window raw data) for reading out pedestal data in the absence of a hit, and to use this instead of type 6, pulse raw data. This leaves us with data types 5 (window raw data), 7 (pulse data) and 8 (combined - pulse data followed by raw data). Window raw data would be used for configuration; pulse data would be the usual hit event readout; the combined format would facilitate algorithm development and monitoring.
- David has already updated and redistributed the document.
- FDC algorithm
- The integration requirements for the 2 detectors are not identical - the CDC has pulses which can start at any time during a window of ~ 1us but all end at the same time, whereas the FDC pulses can start at any time during a shorter window, and are much shorter in duration. There are benefits to having one firmware package which would be used for both FDC and CDC; this would be most useful with software settings to specify that a certain process should be used for the FDC and another for the CDC.
- CDC algorithm
- Beni is going to implement Naomi's timing algorithm for the FDC to see how it performs.
- Cody will experiment with upsampling to get an idea of whether it will be possible to upsample all the data continually or a smaller region, eg 20 samples surrounding a threshold crossing point.