Meeting Time and Place
Wednesday January 15, 2013 at 11:00 AM. At Jefferson Lab, the meeting will be held in F326
Connections
To connect from the outside, please use ESNET
- ) ESNET: 8542553
- )To connect by telephone, dial:
- You can look up toll-free number at http://www.readytalk.com/intl
- US and Canada: (866)740-1260 (toll free)
- International: (303)248-0285 (toll call)
- enter access code followed by the # sign: 3421244#
Agenda
- Announcements
- Status Update
- Tracking
- Calorimetry
- Other systems
- Photon Beam
- Simulations and Calibrations
Minutes
Attending: Sean, Amiran (NU); Curtis (CMU); Simon, Beni, Mike, Eugene, Lubomir, Mark I. (JLab); Zisis (Regina); Richard (UConn); Justin (MIT)
- Status Update
- Not much new since the Collaboration Meeting last week.
- Sean proposed to have a few dedicated meetings for the purpose of integrating the constants into the reconstruction and simulation codes after the upcoming data challenge.
- Tracking
- Naomi reported (in absentia) that she is generating the Garfield tables needed for the CDC time-to-distance relations.
- Other systems
- Richard described the current ideas of what constants will be needed for the photon beamline detectors. There is a wiki page on this subject that he will provide a link to.
- Discussion started with the tagger microscope
- Each fiber is associated with a TDC and fADC250 channel. The TDC will need a time offset, and the fADC will need a gain factor and time offset.
- The ADC pulse shape will be used to match fADC and TDC hits, and the ADC pulse height will be used to determine timewalk corrections for the TDC hits.
- There are 120 channels in the microscope.
- There should be 5 parameters per channel for the timewalk correction. The exact form of the correction is to be determined.
- The high and low energy bounds for each channel in terms of the fraction of the endpoint energy should be stored.
- The endpoint energy as determined in conjunction with the pair spectrometer should be stored.
- The fixed array will need similar constants, it has 220 channels (?)
- The active collimator is not needed for offline reconstruction
- Pair spectrometer (PS):
- The fine-segmented PS is purely hit-based, it checks for hits in coincidence gated with the coarse-grained PS.
- The coarse-grained PS has 8+8 channels, each with an fADC250 channel and TDC channel, with the respective constants needed for each of them.
- The gating threshold may also be needed for reconstruction.
- Total absorption counter
- 8 phototubes viewing a large block, each tube needs t0, gain factor, timewalk correction
- Polarimetry will be discussed in the future.