Spring 2016 Trigger Summary
From GlueXWiki
Revision as of 07:14, 21 March 2017 by Jrsteven (Talk | contribs) (→Monitoring Configuration File Changes)
Contents
[hide]GTP Trigger Summary Table
Mask | Condition | FCAL rings masked | Prescale | Run Start | Run End | Date Range | Log entry |
---|---|---|---|---|---|---|---|
FCAL-BCAL | |||||||
0000001 | 10*FCAL + 3*BCAL > 18000 | 4 | 1 | 10347 | 10490 | 2/18/16 - 2/23/16 | 3383454 |
0000001 | 10*FCAL + 2*BCAL > 18000 && FCAL > 200 | 4 | 1 | 10491 | 11126 | 2/23/16 - 3/31/16 | |
0000001 | 10*FCAL + 2*BCAL > 18000 && FCAL > 200 | 2 | 1 | 11127 | - | 3/31/16 - | 3394095 |
FCAL | |||||||
0000010 | FCAL > 1800 | 4 | 1 | 10347 | 10727 | 2/18/16 - 3/4/16 | |
BCAL | |||||||
0000100 | BCAL > 6000 | N/A | 1 | 10347 | 10490 | 2/18/16 - 2/23/16 | |
0000100 | BCAL > 9000 | N/A | 1 | 10491 | 10832 | 2/23/16 - 3/7/16 | 3383454 |
0000100 | BCAL > 18000 | N/A | 1 | 10833 | 11126 | 3/7/16 - 3/31/16 | |
0000100 | BCAL > 25000 | N/A | 1 | 11127 | - | 3/31/16 - | 3394095 |
PS | |||||||
0001000 | PSC Coincidence | N/A | 3 | 10389 | 11126 | 2/19/16 - 4/1/16 | 3381680 |
0001000 | PSC Coincidence | N/A | 1 | 11127 | - | 4/1/16 - | |
FCAL-BCAL Alternate Equation | |||||||
0010000 | 20*FCAL + 1*BCAL > 36000 && FCAL > 200 | 2 | 1 | 11206 | - | 4/8/16 - | 3397302 |
FCAL-ST Minimum Bias | |||||||
0100000 | FCAL > 900 && # ST hit > 0 | 2 | 2 | 11206 | - | 4/8/16 - | 3397302 |
ST-TAGH Minimum Bias | |||||||
1000000 | ST hit and TAGH hit in energy specified energy range | N/A | ? | ? | ? | ? | ? |
Front Panel Trigger Summary Table
FP Input | FP Bit | Run Start | Date Start | Log entry |
---|---|---|---|---|
FCAL LED | 3 | 11333 | 4/12/16 | 3397348 |
BCAL LED Upstream | 9 | 10506 | 2/24/16 | |
BCAL LED Downstream | 10 | 10506 | 2/24/16 | |
Random pulser | 12 | 11299 | 4/11/16 | 3397771 |
Monitoring Configuration File Changes
The configuration files (e.g. FCAL_BCAL_PS_m7.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2016 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.