Difference between revisions of "ASIC meeting June 14, 2010"

From GlueXWiki
Jump to: navigation, search
(Performance Plots for the ASIC at CMU)
Line 21: Line 21:
 
older preamplifier and that the Struck FADCs we have at CMU are set to a scale such that  
 
older preamplifier and that the Struck FADCs we have at CMU are set to a scale such that  
 
1 volt coresponds to about 4000 channels. We note that the new preamplifier does not exceed
 
1 volt coresponds to about 4000 channels. We note that the new preamplifier does not exceed
~2000 channles here because the output voltage is now (apparently) limited to 0.5V.
+
~2000 channels here because the output voltage is now (apparently) limited to 0.5V.
 
*[[Preamp 4|Preamp 4 : Comparison of scope traces with earlier preamps]]
 
*[[Preamp 4|Preamp 4 : Comparison of scope traces with earlier preamps]]
 
The following sets of plots were taken simply by swapping the old and new preamplifier on the  
 
The following sets of plots were taken simply by swapping the old and new preamplifier on the  
CDC. The high volatge settings were the same and the gas mixture were the same for both. For the
+
CDC. The high voltage settings were the same and the gas mixture were the same for both. For the
 
case of the cosmics with a <i>reduced</i> gain in the new ASIC, we would expect the location of the
 
case of the cosmics with a <i>reduced</i> gain in the new ASIC, we would expect the location of the
 
minimum ionizing peak for cosmics to go down by about a factor of three. Oddly, by just about any reasonable measure, it has moved up. We find this extremely confusing.
 
minimum ionizing peak for cosmics to go down by about a factor of three. Oddly, by just about any reasonable measure, it has moved up. We find this extremely confusing.
*[[Preamp 4: Comparison of cosmic data with original preamp]]'
+
*[[Preamp 4: Comparison of cosmic data with original preamp]]
 
2050V - cosmics - max amplitude histogram
 
2050V - cosmics - max amplitude histogram
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
Line 38: Line 38:
 
|width="415pt"|[[Image:cosmic_energy_2050V_preamp4.jpg|thumb|none|400px|new preamp, cosmics, energy, 50/50 Ar/CO2, 2050V]]
 
|width="415pt"|[[Image:cosmic_energy_2050V_preamp4.jpg|thumb|none|400px|new preamp, cosmics, energy, 50/50 Ar/CO2, 2050V]]
 
|}
 
|}
The following plots are taken with the Fe-55 source for the same pairs of configuration. Here we are limited by a great deal of overflow and saturation in both cases so it is difficult to draw a strong conclusion on were the gain really is on the new ASIC
+
The following plots are taken with the Fe-55 source for the same pairs of configuration. Here we are limited by a great deal of overflow and saturation in both cases so it is difficult to draw a strong conclusion on where the gain really is on the new ASIC
 
*[[Preamp 4: Comparison of 55Fe data with original preamp]]
 
*[[Preamp 4: Comparison of 55Fe data with original preamp]]
  

Revision as of 13:16, 13 June 2010

Meeting Time and Place

Monday June 11, 2010 at 10:00am At Jefferson Lab, the meeting will be held in room F326-327

Connections

To connect from the outside, please use ESNET
1.) ESNET: 8542553
2.) Phone:
+1-800-377-8846 : US
+1-888-276-7715 : Canada
+1-302-709-8424 : International
then enter participant code: 77438230# (remember the "#")

Agenda

Status of the new ASIC

Performance Plots for the ASIC at CMU

The following links go to pages that compare the performance of the older preamplifier to the newest version of the ASIC. We note that the interposer board was not used for the older preamplifier and that the Struck FADCs we have at CMU are set to a scale such that 1 volt coresponds to about 4000 channels. We note that the new preamplifier does not exceed ~2000 channels here because the output voltage is now (apparently) limited to 0.5V.

The following sets of plots were taken simply by swapping the old and new preamplifier on the CDC. The high voltage settings were the same and the gas mixture were the same for both. For the case of the cosmics with a reduced gain in the new ASIC, we would expect the location of the minimum ionizing peak for cosmics to go down by about a factor of three. Oddly, by just about any reasonable measure, it has moved up. We find this extremely confusing.

2050V - cosmics - max amplitude histogram

old preamp, cosmics, amplitude, 50/50 Ar/CO2, 2050V
new preamp, cosmics, amplitude, 50/50 Ar/CO2, 2050V

2050V- cosmics - energy

old preamp, cosmics, energy, 50/50 Ar/CO2, 2050V
new preamp, cosmics, energy, 50/50 Ar/CO2, 2050V

The following plots are taken with the Fe-55 source for the same pairs of configuration. Here we are limited by a great deal of overflow and saturation in both cases so it is difficult to draw a strong conclusion on where the gain really is on the new ASIC

Efficiency Plots for the CDC

The following plot is taken from our NIM article that shows the chamber efficiency as a function of the high voltage setting for various gas mixtures. As can be seen, for the optimal gas mixture (around 50/50), the plateau starts at about 2100 V and there is no efficiency below around 1900V.

HV plateau curve aka efficiency plots.

Status from the FDC

gas gain

efficiency

plateau

amplitude and energy histograms with cosmics & Fe-55

scaling to experiment

Remaining tests

  • At CMU, we are in the process of repeating the efficiency measurements with the new ASIC to see if the combination of the reduced noise and apparent increased gain could be mapped onto the appropriate dynamic range for the CDC. It takes at least a week to collect the cosmic data, and then sometime to analyze.

Schedule to completion

Impact to

detector tests

to installation

Minutes