Difference between revisions of "Action Items"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
 
=== Event generators (should be in the PrimEx analysis directory) ===
 
=== Event generators (should be in the PrimEx analysis directory) ===
  
# Signal Primakoff  
+
1. Signal Primakoff  
# Coherent / incoherent background
+
2. Coherent / incoherent background
# Hardonic background (generate MC samples of contributing decays)
+
3. Hardonic background (generate MC samples of contributing decays)
  
  
  
# Compton with rad corrections
+
4. Compton with rad corrections
 
#* Currently have simple 'Klein Nishina' generator with 1/E energy-dependent spectrum
 
#* Currently have simple 'Klein Nishina' generator with 1/E energy-dependent spectrum
 
#* Need to implement realistic shape of photon spectrum (efficiency)
 
#* Need to implement realistic shape of photon spectrum (efficiency)
# Double Compton Generator (Pavel)
+
5. Double Compton Generator (Pavel)
  
  
# Need to generate MC samples according to realistic run conditions (samples for each run)
+
6. Need to generate MC samples according to realistic run conditions (samples for each run)
  
  
Line 20: Line 20:
 
(need to finalize calibrations before we start reprocessing PrimEx data)
 
(need to finalize calibrations before we start reprocessing PrimEx data)
  
# Timing calibration for FCAL, CCAL  (ST, TOF, BCAL, tagging detectors)
+
1. Timing calibration for FCAL, CCAL  (ST, TOF, BCAL, tagging detectors)
  
# Recalibrate CCAL (non-linearity corrections) -- Drew
+
2. Recalibrate CCAL (non-linearity corrections) -- Drew
 
*: Adjust tagger energy scale -- Sasha
 
*: Adjust tagger energy scale -- Sasha
  
# FCAL calibration
+
3. FCAL calibration
 
*: Do we use official GlueX cluster reconstruction or an Island algorithm ?
 
*: Do we use official GlueX cluster reconstruction or an Island algorithm ?
 
*: How many calibration versions (run periods) we need ? Check with LED data (Chandra)
 
*: How many calibration versions (run periods) we need ? Check with LED data (Chandra)
  
# FCAL dead/suspicious channels in the CCDB (Chandra)
+
4. FCAL dead/suspicious channels in the CCDB (Chandra)
 
*: exclude channels from MC and reconstruction
 
*: exclude channels from MC and reconstruction
  
Line 35: Line 35:
 
=== MC simulation (GEANT) ====
 
=== MC simulation (GEANT) ====
  
#  Tune position of the CCAL according to the survey data
+
1. Adjust position of the CCAL according to the survey data
  
#  Tune CCAL energy reolution
+
2. Adjust position of the FCAK according to the survey data
  
 
+
3. Adjust CCAL energy resolution
CCAL: Tune energy resolution
+

Revision as of 12:37, 11 October 2019

Event generators (should be in the PrimEx analysis directory)

1. Signal Primakoff 2. Coherent / incoherent background 3. Hardonic background (generate MC samples of contributing decays)


4. Compton with rad corrections

    • Currently have simple 'Klein Nishina' generator with 1/E energy-dependent spectrum
    • Need to implement realistic shape of photon spectrum (efficiency)

5. Double Compton Generator (Pavel)


6. Need to generate MC samples according to realistic run conditions (samples for each run)


Calibration

(need to finalize calibrations before we start reprocessing PrimEx data)

1. Timing calibration for FCAL, CCAL (ST, TOF, BCAL, tagging detectors)

2. Recalibrate CCAL (non-linearity corrections) -- Drew

  • Adjust tagger energy scale -- Sasha

3. FCAL calibration

  • Do we use official GlueX cluster reconstruction or an Island algorithm ?
    How many calibration versions (run periods) we need ? Check with LED data (Chandra)

4. FCAL dead/suspicious channels in the CCDB (Chandra)

  • exclude channels from MC and reconstruction


MC simulation (GEANT) =

1. Adjust position of the CCAL according to the survey data

2. Adjust position of the FCAK according to the survey data

3. Adjust CCAL energy resolution