Active Base Radiation Tests

From GlueXWiki
Revision as of 15:40, 15 November 2023 by Aoranliu (Talk | contribs)

Jump to: navigation, search

Active Divider Radiation Test

Measurements
Date Total Dose (kR) Divider current1 (uA) Pulse Amplitude1 (mV) Comment1 Divider current2 (uA) Pulse Amplitude2 (mV) Comment2
2023/11/08 0 kR 388.5 998 mV Positive Voltage 4V, Negative Voltage -4V (in contrast)
2023/11/08 3.2 kR 386.5 951 mV 386.5 937 mV
2023/11/09 7 kR 384.5 923 mV 384.0 898 mV
2023/11/10 10.22 kR 382.5 877 mV 382.5 860 mV
2023/11/13 12.4 kR 381.5 858 mV 380.5 845 mV
2023/11/14 15.6 kR 379.5 825 mV 378.0 787 mV
2023/11/15 19 kR 377.5 142 mV Positive Voltage 4.2V, Negative Voltage -1.7V [1] 376.5 1064 mV Positive Voltage -0.7V, Negative Voltage -3.4V [2]
19 kR 378.5 808 mV Regulator removed [3] 376.5 1064 mV Regulator removed [4]