Difference between revisions of "Analysis Shift Meeting Agenda, November 07 - November 13, 2021"

From GlueXWiki
Jump to: navigation, search
Line 8: Line 8:
 
# Physics on ρ<sup>0 channel of Run 90059
 
# Physics on ρ<sup>0 channel of Run 90059
 
# Trigger Discussion
 
# Trigger Discussion
##2 Triggers:
+
##2 triggers: Main production:
 +
###Bit 1 BCAL + FCAL + SC
 +
###bit2=  BCAL + FCAL  with larger energy threshold
 +
###bit 3 =PS
 
##FCAl and BCAL minimum ionizing (1)
 
##FCAl and BCAL minimum ionizing (1)
 
##Start counter
 
##Start counter

Revision as of 21:50, 10 November 2021

Wednesday, November 10

  1. Beam Update
  2. Production Run Update
    1. List of good runs is on the analysis shift page. Calibration can start for some subdetectors.
    2. Discussed the current progress regarding the run spreadsheet and the data quality spreadsheet
    3. Need to have a summary slides of the important plots to monitor for the data quality spreadsheet
  3. Physics on ρ0 channel of Run 90059
  4. Trigger Discussion
    1. 2 triggers: Main production:
      1. Bit 1 BCAL + FCAL + SC
      2. bit2= BCAL + FCAL with larger energy threshold
      3. bit 3 =PS
    2. FCAl and BCAL minimum ionizing (1)
    3. Start counter
    4. Will kill some physics, primakov production, excited nucleon or recoil on coherent only neutrals (2) in final state
    5. To account for this, add trigger with larger energy threshold to accept primakov style events
    6. Completelmentary, has larger energy deposition
    7. Primakov is z^2 hunting for small enhancement bumble in angle dis. Or eta, would be big peak with carbons.
      1. larger eta mass than pion
      2. larger the target the better, enhancement for primakov
      3. pi0 in hall b (primakov in carbon)
      4. more physics, sensitive to this
      5. 50 kHz with 90% live time
    8. Adding TPOL yesterday
      1. will use it somewhere eventually
    9. Ahead of schedule
      1. already have production data on he 4
      2. Took AMO that can used in
    10. For Flux,
      1. tagger and PS needs to be calibrated
      2. estimate is total number of PS triggers
      3. integral of PS spectrum
    11. Insert calorimeter into beam, count photons. In parallel, run PS, so you know acceptance, convulsion of PS converter (thickness and sigma) acceptance

Tuesday, November 09

  1. Radiator
  2. Timing Cuts
  3. Bo and Phoebe's input from the spreadsheets
    1. Discussed updates to Analysis shift and analysis shift webpage
  4. Possible take a look over the run files that we have, if they get ready

Monday, November 08