# Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and  simulation with a point-to-point precision of at least 5%.
 
# Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and  simulation with a point-to-point precision of at least 5%.
# Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at east 5 MeV.
+
# Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at least 5 MeV.
 
# Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.
 
# Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.
  

Revision as of 16:37, 3 April 2020

Meeting Time: 11:00 a.m.

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/907185247.
  2. To join via Polycom room system go to the IP Address: 199.48.152.152 (bjn.vc) and enter the meeting ID: 907185247.
  3. To join via phone, use one of the following numbers and the Conference ID: 907185247.
    • US or Canada: +1 408 740 7256 or
    • US or Canada: +1 888 240 2560
  4. Upon connection all microphones are automatically muted. To unmute your mike on a Polycom or equivalent unit, enter *4. Unmuting on a computer is trivial as there is a microphone button than can be clicked.
  5. More information on connecting to bluejeans is available.

Participant Direct Lines

  • JLab Phone in CC L207 is 757-269-7084 (usual room)
  • JLab Phone: in CC F326 is 757-269-6460
  • Phone in the Regina Video-conference Suite is 306-585-4204
  • Athens Phone: in Christina's office is 011-30-210-727-6947

References

  1. FCAL HDFCAL log book
  2. BCAL HDBCAL log book

Goals for Calorimetry Group

  1. Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
  2. Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at least 5 MeV.
  3. Demonstrate agreement of photon reconstruction efficiency and resolution between data and simulation as a function of E, phi and theta to within 5%.

Action Items

  1. Check switches on FCAL board with high scaler rates and make sure it is set to 2 V full scale. (Colin and Sasha)

Long term items

Tentative Agenda

  1. Announcements
  2. Action Items
  3. Run Updates
    1. FCAL
    2. BCAL
  4. Calibrations
  5. Monitoring
  6. Reconstruction
  7. Efficiencies
  8. Simulations
  9. NIM articles
  10. Any other business

Minutes

Attending: