Difference between revisions of "Attenuation Results from Radphi"

From GlueXWiki
Jump to: navigation, search
Line 2: Line 2:
  
 
{|align="center"
 
{|align="center"
|[[Image:lgdatten.gif|thumb|Measured attenuation length vs photon energy for Russian lead glass used by the Radphi experiment ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdatten.eps eps]).]]
+
|valign="top" [[Image:lgdatten.gif|thumb|Measured attenuation length vs photon energy for Russian lead glass used by the Radphi experiment ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdatten.eps eps]).]]
|[[Image:lgdeff.gif|thumb|Quantum efficiency of PMT used with LGD by Radphi ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdeff.eps eps]).]]
+
|valign="top" [[Image:lgdeff.gif|thumb|Quantum efficiency of PMT used with LGD by Radphi ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdeff.eps eps]).]]
 
|-
 
|-
|[[Image:lgdN0.gif|thumb|Cerenkov N0 parameter of LGD from MC Cerenkov simulation as a function of emission angle of photon with respect to the LGD axis  ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdN0.eps eps]).]]
+
|valign="top" [[Image:lgdN0.gif|thumb|Cerenkov N0 parameter of LGD from MC Cerenkov simulation as a function of emission angle of photon with respect to the LGD axis  ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdN0.eps eps]).]]
|[[Image:lgdeff_atten.gif|thumb|Effective attenuation length of LGD in Radphi, from MC Cerenkov simulation, as a function of emission z coordinate along the length of the block ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdeff_atten.eps eps]).]]
+
|valign="top" [[Image:lgdeff_atten.gif|thumb|Effective attenuation length of LGD in Radphi, from MC Cerenkov simulation, as a function of emission z coordinate along the length of the block ([http://zeus.phys.uconn.edu/radphi/calibration/attenuation/lgdeff_atten.eps eps]).]]
 
|}
 
|}

Revision as of 13:36, 29 January 2008

inserting plots here, under construction by rtj

valign="top"
Measured attenuation length vs photon energy for Russian lead glass used by the Radphi experiment (eps).
valign="top"
Quantum efficiency of PMT used with LGD by Radphi (eps).
valign="top"
Cerenkov N0 parameter of LGD from MC Cerenkov simulation as a function of emission angle of photon with respect to the LGD axis (eps).
valign="top"
Effective attenuation length of LGD in Radphi, from MC Cerenkov simulation, as a function of emission z coordinate along the length of the block (eps).