BCAL Beam Test Plots, November 20, 2006

From GlueXWiki
Revision as of 17:58, 17 November 2006 by Leverinb (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

First go

  • Gain Correction:
    1. Establish the means of each cell in the Monte Carlo and find the ratio wrt Cell 8
    2. Find the current ratio of each ADC in the beamtest data wrt to North 8
    3. Correct the ADC ratio to match the Monte Carlo Ratios
      • The ratio of Cell 8 to North 8 defines the MeV/Channel


How does this look over the entire tagger spectrum? Over a particular energy cut?