Line 1: Line 1:
[[Image:Ebeamecal.gif|400px]]
+
* (Figure 1.) ''<math>E_{beam}/E_{cal}</math>'' distribution using Monte Carlo corrected phototube calibration factors
 +
[[Image:Ebeamecal.gif|thumb|400px|left|Figure 1.]]
 +
<br style="clear:both;"/>
  
[[Image:Z 200to250.gif|thumb|100px|left]]
+
* (Figure 2.) Plots of Z for different beam energy cuts where : <math> z = \frac{E_{cal} - E_{beam}}{E_{beam}} </math>
[[Image:Z 250to300.gif|thumb|100px|left]]
+
Figure 2.
[[Image:Z 300to350.gif|thumb|100px|left]]
+
[[Image:Z 200to250.gif|thumb|100px|left|(a) 0.20 to 0.25 GeV]]
[[Image:Z 350to400.gif|thumb|100px|left]]
+
[[Image:Z 250to300.gif|thumb|100px|left|(b) 0.25 to 0.30 GeV]]
[[Image:Z 400to450.gif|thumb|100px|left]]
+
[[Image:Z 300to350.gif|thumb|100px|left|(c) 0.30 to 0.35 GeV]]
[[Image:Z 450to500.gif|thumb|100px|left]]
+
[[Image:Z 350to400.gif|thumb|100px|left|(d) 0.35 to 0.40 GeV]]
[[Image:Z 500to550.gif|thumb|100px|left]]
+
[[Image:Z 400to450.gif|thumb|100px|left|(e) 0.40 to 0.45 GeV]]
[[Image:Z 550to600.gif|thumb|100px|left]]
+
[[Image:Z 450to500.gif|thumb|100px|left|(f) 0.45 to 0.50 GeV]]
 +
[[Image:Z 500to550.gif|thumb|100px|left|(g) 0.50 to 0.55 GeV]]
 +
[[Image:Z 550to600.gif|thumb|100px|none|(h) 0.55 to 0.60 GeV]]
 +
<br style="clear:both;"/>
  
  
[[Image:Mean vs Ebeam.gif|400px]]
+
* (Figure 3.)Means vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data
 +
[[Image:Mean vs Ebeam.gif|400px|thumb|left|Figure 3.]]
 +
<br style="clear:both;"/>
  
Means vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data
+
* (Figure 4.)Sigma vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data. The curve is a fit to the function a/sqrt(E[Gev]) + b where and a = 0.046 +/- 0.005 and b = 0.033 +/- 0.005. This is very similar to Alex's note from December 16, 2006 where a = 0.050 and b = 0.020.
 
+
[[Image:Sigma vs Ebeam.gif|400px|thumb|left|Figure 4.]]
[[Image:Sigma vs Ebeam.gif|400px]]
+
<br style="clear:both;"/>
 
+
Sigma vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data. The curve is a fit to the function a/sqrt(E[Gev]) + b where and a = 0.046 +/- 0.005 and b = 0.033 +/- 0.005. This is very similar to Alex's note from December 16, 2006 where a = 0.050 and b = 0.020.
+

Revision as of 14:08, 20 December 2006

  • (Figure 1.) E_{{beam}}/E_{{cal}} distribution using Monte Carlo corrected phototube calibration factors
Figure 1.


  • (Figure 2.) Plots of Z for different beam energy cuts where : z={\frac  {E_{{cal}}-E_{{beam}}}{E_{{beam}}}}

Figure 2.

(a) 0.20 to 0.25 GeV
(b) 0.25 to 0.30 GeV
(c) 0.30 to 0.35 GeV
(d) 0.35 to 0.40 GeV
(e) 0.40 to 0.45 GeV
(f) 0.45 to 0.50 GeV
(g) 0.50 to 0.55 GeV
(h) 0.55 to 0.60 GeV



  • (Figure 3.)Means vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data
Figure 3.


  • (Figure 4.)Sigma vs E_{beam} from Gaussian fits of z from Monte Carlo corrected data. The curve is a fit to the function a/sqrt(E[Gev]) + b where and a = 0.046 +/- 0.005 and b = 0.033 +/- 0.005. This is very similar to Alex's note from December 16, 2006 where a = 0.050 and b = 0.020.
Figure 4.