# Data output: /gluex/Subsystems/BCAL/data/south4  
 
# Data output: /gluex/Subsystems/BCAL/data/south4  
 
#:::                  /gluex/Subsystems/BCAL/data/north4  (default)
 
#:::                  /gluex/Subsystems/BCAL/data/north4  (default)
 +
# Due to some glitches in the firmware you have to start run first and then disable the external trigger

Revision as of 13:58, 31 March 2014

  1. Login to gluon49 under hdops
  2. source /gluex/Subsystems/BCAL/setupcoda3
  3. Start DAQ for 4 north or south crates: bcal_N4_start or bcal_S4_start
    terminate all DAQ processes bcal_N4_exit
  4. Choose configuration: Configurations-->Coda Config-->bcal_s4 (or bcal_n4)
  5. Settings in the Run Control (you have to set these variables once if you edit coda configuration with jcedit)
    Set User --> Runtime Variables --> Config File to /gluex/Subsystems/BCAL/bcal_pulser_ti/pulse
    Set User --> Runtime Variables --> List --> %(CODA_ROL) to /gluex/release/0.1/src/rol/bcal_base_ti
  6. FADC250 configuration files are located in /gluex/Subsystems/BCAL/bcal_pulser_ti
  7. Data output: /gluex/Subsystems/BCAL/data/south4
    /gluex/Subsystems/BCAL/data/north4 (default)
  8. Due to some glitches in the firmware you have to start run first and then disable the external trigger