CDC Pedestal Studies

From GlueXWiki
Revision as of 16:13, 23 June 2015 by Zihlmann (Talk | contribs)

Jump to: navigation, search

Pedestal Subtraction

Based on cosmic ray data with BCAL trigger Look for events with the following signature in the CDC:

  • Wave form of CDC signal

The first test was done by using the region P_{{i}} (blue) to determine a pedestal and the region I (red) to determine an Integral and then subtract the proper pedestal from the Intergral as follows: D=I-P_{{i}}/N_{{i}}*80. where N_{{i}} is the number of samples used to calculate the pedestal and 80 is the number of samples in the Integral I. In the case of no signal the the distribution D is expected to be around zero with a sigma that reflects the resolution and depends on the number samples N_{{i}} used in determining the pedestal.