Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical
 
Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical
 
Picked events with hits in 3 straws in same vertical column in prototype.  Estimate from detector geometry that track angle < 14 degrees to vertical.
 
Picked events with hits in 3 straws in same vertical column in prototype.  Estimate from detector geometry that track angle < 14 degrees to vertical.
 +
 +
{| border="0" cellpadding="2"
 +
|+ Real life results from prototype 2100V 50/50 Ar/CO2 with scintillators vertical
 +
|[[Image:cdc_run_31962_drifttime.png|thumb|x200px|Drift time (- offset) in ns]]
 +
|[[Image:cdc_run_31962_maxampfit.png|thumb|x200px|First max in signal amplitude]]
 +
|[[Image:cdc_run_31962_integration.png|thumb|x200px|Integrated signal]]
 +
|}

Revision as of 10:49, 18 April 2014

Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical Picked events with hits in 3 straws in same vertical column in prototype. Estimate from detector geometry that track angle < 14 degrees to vertical.

Real life results from prototype 2100V 50/50 Ar/CO2 with scintillators vertical
File:Cdc run 31962 drifttime.png
Drift time (- offset) in ns
First max in signal amplitude
Integrated signal