Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical
 
Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical
Picked events with hits in 3 straws in same vertical column in prototype.  Estimate from detector geometry that track angle < 14 degrees to vertical.
 
  
{| border="0" cellpadding="2"
 
|+ Real life results from prototype 2100V 50/50 Ar/CO2 with scintillators vertical
 
|[[Image:cdc_run_31962_maxampfit.png|thumb|x200px|First max in signal amplitude]]
 
|[[Image:cdc_run_31962_integration.png|thumb|x200px|Integrated signal]]
 
|}
 
  
{| border="0" cellpadding="2"
 
|+ Garfield, 3GeV u at 0-14degrees, gain 3.84e6 (gas gain) x 0.058 (transfer function)
 
|[[Image:cdc_garf_31962b_amp.png|thumb|x200px|First max in signal amplitude]]
 
|[[Image:cdc_garf_31962b_int.png|thumb|x200px|Integrated signal]]
 
|}
 
  
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
Line 20: Line 9:
 
|}
 
|}
  
{| border="0" cellpadding="2"
 
|+ Garfield, 3GeV u at 0-5degrees, gain 3.84e6 (gas gain) x 0.058 (transfer function)
 
|[[Image:cdc_garf_31962d_amp.png|thumb|x200px|First max in signal amplitude]]
 
|[[Image:cdc_garf_31962d_int.png|thumb|x200px|Integrated signal]]
 
|}
 
  
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
|+ Garfield, 3GeV u at 0-5degrees, gain 3.84e6 (gas gain) x 0.058 (transfer function), window resolution 8ns
+
|+ Garfield, 3GeV u at 0-5degrees, gain 6.7e5 (gas gain) x 0.058 (transfer function), window resolution 8ns
 
|[[Image:cdc_garf_31962j_8ns_amp.png|thumb|x200px|First max in signal amplitude]]
 
|[[Image:cdc_garf_31962j_8ns_amp.png|thumb|x200px|First max in signal amplitude]]
 
|[[Image:cdc_garf_31962j_8ns_int.png|thumb|x200px|Integrated signal]]
 
|[[Image:cdc_garf_31962j_8ns_int.png|thumb|x200px|Integrated signal]]
 
|}
 
|}

Latest revision as of 14:48, 21 April 2014

Cosmics from prototype data of run 31962, 50/50 Ar/CO2, 2100V, scintillators above and below prototype with paddles vertical


Real life results from prototype 2100V 50/50 Ar/CO2 with scintillators vertical and track angle < 5 degr to vertical
First max in signal amplitude, track angle < 5 degr to vertical
Integrated signal, track angle <5 degr to vertical


Garfield, 3GeV u at 0-5degrees, gain 6.7e5 (gas gain) x 0.058 (transfer function), window resolution 8ns
First max in signal amplitude
Integrated signal