Difference between revisions of "CDC prototype drift times"
From GlueXWiki
(Created page with "{| border="0" cellpadding="2" |width="900pt"| [[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold...") |
|||
Line 1: | Line 1: | ||
+ | |||
+ | CDC prototype cosmics data | ||
+ | |||
+ | *50/50 mixed Ar, CO<sub>2</sub> | ||
+ | *Recalibrated MFCs | ||
+ | *Outer plenum added to CDC prototype to prevent leaks | ||
+ | *New pre-production HVB | ||
+ | *2100V | ||
+ | *Modified preamp4 (terminating resistors removed) | ||
+ | *Prototype tilted at 30<sup>o</sup> to enclosing scintillators (scints trigger the daq) | ||
+ | *New timing setup (recording coinc logic signal) | ||
+ | |||
+ | Purple histogram is drift time in tracks through each straw; gray selects tracks through all 3 straws in same column | ||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|width="900pt"| | |width="900pt"| | ||
[[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 5 sigma ]] | [[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 5 sigma ]] | ||
+ | |} | ||
+ | |||
+ | {| border="0" cellpadding="2" | ||
+ | |width="900pt"| | ||
+ | [[Image:run_31716_drifttime_columns_thr10.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 10 sigma ]] | ||
|} | |} |
Revision as of 15:29, 17 November 2011
CDC prototype cosmics data
- 50/50 mixed Ar, CO2
- Recalibrated MFCs
- Outer plenum added to CDC prototype to prevent leaks
- New pre-production HVB
- 2100V
- Modified preamp4 (terminating resistors removed)
- Prototype tilted at 30o to enclosing scintillators (scints trigger the daq)
- New timing setup (recording coinc logic signal)
Purple histogram is drift time in tracks through each straw; gray selects tracks through all 3 straws in same column