Difference between revisions of "CDC prototype drift times"

From GlueXWiki
Jump to: navigation, search
(Created page with "{| border="0" cellpadding="2" |width="900pt"| [[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold...")
 
Line 1: Line 1:
 +
 +
CDC prototype cosmics data
 +
 +
*50/50 mixed Ar, CO<sub>2</sub>
 +
*Recalibrated MFCs
 +
*Outer plenum added to CDC prototype to prevent leaks
 +
*New pre-production HVB
 +
*2100V
 +
*Modified preamp4 (terminating resistors removed)
 +
*Prototype tilted at 30<sup>o</sup> to enclosing scintillators (scints trigger the daq)
 +
*New timing setup (recording coinc logic signal)
 +
 +
Purple histogram is drift time in tracks through each straw; gray selects tracks through all 3 straws in same column
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
 
|width="900pt"|
 
|width="900pt"|
 
[[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 5 sigma ]]
 
[[Image:run_31716_drifttime_columns_thr5.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 5 sigma ]]
 +
|}
 +
 +
{| border="0" cellpadding="2"
 +
|width="900pt"|
 +
[[Image:run_31716_drifttime_columns_thr10.png|thumb|900px|drift times for all tracks and tracks in single column of straws, threshold 10 sigma ]]
 
|}
 
|}

Revision as of 15:29, 17 November 2011

CDC prototype cosmics data

  • 50/50 mixed Ar, CO2
  • Recalibrated MFCs
  • Outer plenum added to CDC prototype to prevent leaks
  • New pre-production HVB
  • 2100V
  • Modified preamp4 (terminating resistors removed)
  • Prototype tilted at 30o to enclosing scintillators (scints trigger the daq)
  • New timing setup (recording coinc logic signal)

Purple histogram is drift time in tracks through each straw; gray selects tracks through all 3 straws in same column

drift times for all tracks and tracks in single column of straws, threshold 5 sigma
drift times for all tracks and tracks in single column of straws, threshold 10 sigma