Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs
+
Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs.
 +
Used same hit thresholds & window for all runs.
 +
 
  
 
<h2>Run 2451</h2>
 
<h2>Run 2451</h2>

Revision as of 15:42, 26 March 2015

Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs. Used same hit thresholds & window for all runs.


Run 2451

Last run of 2014

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Garfield 5475-4525 Ar-CO2 has tmax ~560ns

Run 2551

After disengaging the alcohol bubbler. March 2-3 2015

Run 2560

After changing the CO2 gas factor from 0.773 to 0.74

Run 2616

After changing the gas mixer MFCs from master/slave to independent, March 11

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2617

March 11

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns

Run 2619

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2644

After moving CO2 controller from ch2 to ch4 and decreasing sparsification thresholds

Run 2649