CDC recent run drift times

From GlueXWiki
Revision as of 09:19, 27 March 2015 by Njarvis (Talk | contribs)

Jump to: navigation, search

Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs. Used same hit thresholds & window for all runs.


Run 2451

7 Feb 2015. First run of 2015. Increased sparsification thresholds from 7sigma to 18sigma

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Garfield 5475-4525 Ar-CO2 has tmax ~560ns

Run 2551

2-3 March 2015. 3 weeks after disengaging the alcohol bubbler.

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2560

8 March 2015. 5 days after changing the CO2 gas factor from 0.773 to 0.74

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2577

10 March 2015.

Run 2616

11 March 2015. 2 days after changing the gas mixer MFCs from master/slave to independent

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Run 2617

March 11

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns

Run 2619

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2644

After moving CO2 controller from ch2 to ch4 and decreasing sparsification thresholds

Run 2649

After returning CO2 controller from ch4 to ch2

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal