Difference between revisions of "CDC run 1280 bad events"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
 
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
 
|+ Run 1280 Evt 14992 roc 26 slot 3 chan 56
 
|+ Run 1280 Evt 14992 roc 26 slot 3 chan 56
Line 23: Line 22:
 
sample: 58  original: 2556  upsampled:  2499  2423  2327  2233  2164
 
sample: 58  original: 2556  upsampled:  2499  2423  2327  2233  2164
 
sample: 59  original: 2094  upsampled:  2140  2164  2233  2327  2422
 
sample: 59  original: 2094  upsampled:  2140  2164  2233  2327  2422
 +
 +
</pre>Searching for ADC value >= 300
 +
  ADC[36] 100
 +
  ADC[37] 102
 +
  ADC[38] 103
 +
  ADC[39] 108
 +
  ADC[40] 111
 +
  ADC[41] 108
 +
  ADC[42] 98
 +
  ADC[43] 89
 +
  ADC[44] 77
 +
  ADC[45] 57
 +
  ADC[46] 44
 +
  ADC[47] 51
 +
  ADC[48] 71
 +
  ADC[49] 94
 +
  ADC[50] 117
 +
  ADC[51] 174
 +
  ADC[52] 375
 +
adc_subset[0] 89
 +
adc_subset[1] 77
 +
adc_subset[2] 57
 +
adc_subset[3] 44
 +
adc_subset[4] 51
 +
adc_subset[5] 71
 +
adc_subset[6] 94
 +
adc_subset[7] 117
 +
adc_subset[8] 174
 +
adc_subset[9] 375
 +
adc_subset[10] 257
 +
adc_subset[11] 1287
 +
adc_subset[12] 1294
 +
adc_subset[13] 2196
 +
adc_subset[14] 2423
 +
thresholds: hi 231 lo 111
 +
threshold 231 met or exceeded by sample 9 value 375
 +
adc[8] 174
 +
adc[7] 117
 +
adc[6] 94
 +
threshold 111 met or preceded by sample 6 value 94
 +
itime1 60 x 0.1 samples
 +
upsampled 0 91
 +
upsampled 1 97
 +
upsampled 2 102
 +
upsampled 3 107
 +
upsampled 4 110
 +
upsampled 5 109
 +
upsampled 6 107
 +
upsampled 7 107
 +
threshold 111 met or preceded by upsampled point 7 value 107
 +
itime2 14 x 0.1 samples
 +
denom -107 limit 8
 +
 +
<pre>
  
 
</pre>
 
</pre>

Revision as of 11:04, 25 November 2014

Run 1280 Evt 14992 roc 26 slot 3 chan 56
original
upsampled
both
sample: 45  original:   57  upsampled:    57    54    50    48    46
sample: 46  original:   44  upsampled:    45    44    45    46    49
sample: 47  original:   51  upsampled:    51    55    59    63    67
sample: 48  original:   71  upsampled:    72    76    81    86    92
sample: 49  original:   94  upsampled:    98   103   107   110   110
sample: 50  original:  117  upsampled:   108   107   113   130   162
sample: 51  original:  174  upsampled:   207   260   311   346   353
sample: 52  original:  375  upsampled:   331   287   241   220   245
sample: 53  original:  257  upsampled:   334   485   680   889  1075
sample: 54  original: 1287  upsampled:  1212  1289  1316  1316  1323
sample: 55  original: 1294  upsampled:  1365  1458  1602  1780  1962
sample: 56  original: 2196  upsampled:  2126  2254  2342  2399  2436
sample: 57  original: 2423  upsampled:  2469  2502  2534  2552  2542
sample: 58  original: 2556  upsampled:  2499  2423  2327  2233  2164
sample: 59  original: 2094  upsampled:  2140  2164  2233  2327  2422

Searching for ADC value >= 300
 ADC[36] 100
 ADC[37] 102
 ADC[38] 103
 ADC[39] 108
 ADC[40] 111
 ADC[41] 108
 ADC[42] 98
 ADC[43] 89
 ADC[44] 77
 ADC[45] 57
 ADC[46] 44
 ADC[47] 51
 ADC[48] 71
 ADC[49] 94
 ADC[50] 117
 ADC[51] 174
 ADC[52] 375

adc_subset[0] 89 adc_subset[1] 77 adc_subset[2] 57 adc_subset[3] 44 adc_subset[4] 51 adc_subset[5] 71 adc_subset[6] 94 adc_subset[7] 117 adc_subset[8] 174 adc_subset[9] 375 adc_subset[10] 257 adc_subset[11] 1287 adc_subset[12] 1294 adc_subset[13] 2196 adc_subset[14] 2423 thresholds: hi 231 lo 111 threshold 231 met or exceeded by sample 9 value 375 adc[8] 174 adc[7] 117 adc[6] 94 threshold 111 met or preceded by sample 6 value 94 itime1 60 x 0.1 samples upsampled 0 91 upsampled 1 97 upsampled 2 102 upsampled 3 107 upsampled 4 110 upsampled 5 109 upsampled 6 107 upsampled 7 107 threshold 111 met or preceded by upsampled point 7 value 107 itime2 14 x 0.1 samples denom -107 limit 8