Difference between revisions of "CDC straight straws"
From GlueXWiki
Line 195: | Line 195: | ||
|[[Image:cdc_run_32292_5149_tz16_tfix1000_res30_5mm.png|thumb|x250px|Resolution ch30, drift radius > 5mm, >80% hits on track]] | |[[Image:cdc_run_32292_5149_tz16_tfix1000_res30_5mm.png|thumb|x250px|Resolution ch30, drift radius > 5mm, >80% hits on track]] | ||
|} | |} | ||
− | + | ||
− | x and y resolution for ch34, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2 | + | x and y resolution for ch34, driftradius>5mm, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2 |
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|[[Image:cdc_run_32292_5149_tz16_tfix1000_res34_5mm.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track]] | |[[Image:cdc_run_32292_5149_tz16_tfix1000_res34_5mm.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track]] | ||
|[[Image:cdc_run_32292_5149_tz16_tfix1000_rx34_5mm.png|thumb|x250px|X resolution ch34, drift radius > 5mm, >80% hits on track]] | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rx34_5mm.png|thumb|x250px|X resolution ch34, drift radius > 5mm, >80% hits on track]] | ||
|[[Image:cdc_run_32292_5149_tz16_tfix1000_ry34_5mm.png|thumb|x250px|Y resolution ch34, drift radius > 5mm, >80% hits on track]] | |[[Image:cdc_run_32292_5149_tz16_tfix1000_ry34_5mm.png|thumb|x250px|Y resolution ch34, drift radius > 5mm, >80% hits on track]] | ||
+ | |} | ||
+ | |||
+ | same again after moving tabled position of wire 34 from x,y to x-180um,y | ||
+ | {| border="0" cellpadding="2" | ||
+ | |[[Image:cdc_run_32292_5149_tz16_tfix1000_res34_5mm_w.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um]] | ||
+ | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rx34_5mm_w.png|thumb|x250px|X resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um]] | ||
+ | |[[Image:cdc_run_32292_5149_tz16_tfix1000_ry34_5mm_w.png|thumb|x250px|Y resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um]] | ||
|} | |} |
Revision as of 15:45, 26 June 2013
Drift time fit Estimate of t0 is 850.09 and tmax is 1464.19, difference is 614.10 Straight-line intercept is 834.51, to match histogram fit t0, use tz_add 15.58
Resolutions using tz=16 and Garfield for 2100V, 51Ar, 49CO2
Different scint orientations
Drift time fits, hit threshold 5#sigma
Hit threshold 6#sigma
Hit threshold 6#sigma
-dist(mm) | 8mm (2kV) | 9mm (2.1kV) | 10mm (2.1kV) |
---|---|---|---|
6mm | 381 | 387 | 394 |
7mm | 527 | 535 | 544 |
7.5mm | 608 | 618 | 628 |
7.8mm | 660 | 670 | 681 |
8mm | 706 | 717 | |
8.5mm | 800 | 813 | |
9mm | 914 | ||
9.5mm | 1020 |
Drift time fit, ch 30, hit threshold 6#sigma
Resolution for ch30, hit threshold 6#sigma
Resolution for ch30, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2
x and y resolution for ch34, driftradius>5mm, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2
same again after moving tabled position of wire 34 from x,y to x-180um,y