Difference between revisions of "CDC time spikes"

From GlueXWiki
Jump to: navigation, search
Line 20: Line 20:
 
|}
 
|}
  
Same data after more normal analysis
+
Same data after more normal analysis (Search forward to find pedestal+5sigma crossing, then backwards to find 4sigma and then 1sigma crossings)
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
 
|[[Image:run_31955_track119_5sigx.png|thumb|x150px|5sigma crossing]]
 
|[[Image:run_31955_track119_5sigx.png|thumb|x150px|5sigma crossing]]

Revision as of 17:11, 13 November 2012

Trigger signals

Scint and coinc logic signals, scope triggered on coinc (magenta)
Same, with TI busy signal (green)
Same, different timebase


Histograms of threshold-crossing bins in central bank of 16 straws, different thresholds (ignore the histo titles)

ADC-value=150 crossing (~approx ped + 5sigma)
3.5sigma crossing (approx ADC value 112 = (55 + 3x16.5))
ADC-value=100 crossing


Histograms of ADC value=100 threshold-crossing bins in individual straws (search started at bin 160)

ADC-value=100 crossing

Same data after more normal analysis (Search forward to find pedestal+5sigma crossing, then backwards to find 4sigma and then 1sigma crossings)

5sigma crossing
4sigma crossing
1sigma crossing
extrapolation to local pedestal crossing
drift time (ns)