Difference between revisions of "CDC transfer func attempt"

From GlueXWiki
Jump to: navigation, search
m (Text replacement - "http://argus.phys.uregina.ca/cgi-bin/private" to "https://halldweb.jlab.org/doc-private")
 
(10 intermediate revisions by one other user not shown)
Line 6: Line 6:
 
<h4>Circuit</h4>
 
<h4>Circuit</h4>
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
|[[Image:cdc_charge_inj.png|thumb|x100px|Charge injection circuit from Fernando's [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=1364 GlueX-doc-1364] ]]
+
|[[Image:cdc_charge_inj.png|thumb|x100px|Charge injection circuit from Fernando's [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=1364 GlueX-doc-1364] ]]
 
|}
 
|}
  
Actual component values used were... 51.1 Ohms, 908 Ohms and 2pF
+
Actual component values used were... 51.1 Ohms, 908 Ohms and 2pF.
 +
 
 +
The aim is to inject a charge impulse into the electronics chain and measure its response.
  
 
<h4>Early results</h4>
 
<h4>Early results</h4>
Line 62: Line 64:
  
  
Integrated value of transfer function is 19.03 adc_units.us
+
Input charge: 2 pF x 103 mV = 206 fC
 +
 
 +
Input current: divide by 12ns peaking time of preamp: 206 fC / 12 ns = 17.2 uA
 +
 
 +
 
 +
Peak value of output data is 635 adc_units ~ 635 * 495 mV / 4096 = 76.7 mV
 +
 
 +
Electronics gain is 76.7 mV / 206 fC = 0.37 mV/fC 
 +
 
 +
(Gain of preamp alone measured earlier (before modifications) by FJB as 0.57 mV/fC)
 +
 
 +
 
 +
Convert to current using 50 Ohm resistance: 76.7 mV / 50 Ohm = 1.53 mA
 +
 
 +
 
 +
Current gain is 1.53 mA / 17.2 uA = 89.0
 +
 
 +
 
 +
Integrated value of output data is 19.03 adc_units.us ~ 19.03 * 495 mV / 4096 = 2.30 mV.us
 +
 
 +
Convert to charge using 50 Ohm resistance: 2.3 mV.us / 50 Ohm = 0.046 mA.us = 0.046 nC = 46 pC
 +
 
 +
 
 +
Charge gain is 46 pC / 206 fC = 223
 +
 
 +
 
 +
To convert histograms of summed ADC data (with 8ns sample time) to charge, multiply by 8 ns * 46 pC / 19.03 us = 19.3 fC
 +
 
 +
 
 +
Garfield uses uA for signals, but I want to see the resulting histograms in adc units, for direct comparison with cosmics data.  So... I need to convert my impulse response to input of 1 uA, ie use (1 / 17.2) * fitted function above as the transfer function.??  (Fitted function already includes current gain x 89).
 +
 
 +
The remaining gain factor needed to match garfield adc data to real life data is the gas gain.

Latest revision as of 16:48, 24 February 2017

Setup
Setup (GS 4001)

Circuit

Charge injection circuit from Fernando's GlueX-doc-1364

Actual component values used were... 51.1 Ohms, 908 Ohms and 2pF.

The aim is to inject a charge impulse into the electronics chain and measure its response.

Early results

100mV leading edge of sq wave step up (yellow) and trigger from pulser (purple) - average
output of shaper - average
output of shaper - expanded time scale
output of fadc - average
output of fadc - expanded time scale

Final results

Borrowed Phillips 5771 (no attenuators needed)

pulser output - single
pulser output - average
pulser output - average


output of shaper - single
output of shaper - average
output of shaper - average
fADC data
upsampled fADC data

Fitted function

mean of upsampled fADC data
fitted function
blue=refit with powers fixed, pink= pars 137, 118, 8, 91.4, 9

Beware typos in filenames, this was run #31941!


Input charge: 2 pF x 103 mV = 206 fC

Input current: divide by 12ns peaking time of preamp: 206 fC / 12 ns = 17.2 uA


Peak value of output data is 635 adc_units ~ 635 * 495 mV / 4096 = 76.7 mV

Electronics gain is 76.7 mV / 206 fC = 0.37 mV/fC

(Gain of preamp alone measured earlier (before modifications) by FJB as 0.57 mV/fC)


Convert to current using 50 Ohm resistance: 76.7 mV / 50 Ohm = 1.53 mA


Current gain is 1.53 mA / 17.2 uA = 89.0


Integrated value of output data is 19.03 adc_units.us ~ 19.03 * 495 mV / 4096 = 2.30 mV.us

Convert to charge using 50 Ohm resistance: 2.3 mV.us / 50 Ohm = 0.046 mA.us = 0.046 nC = 46 pC


Charge gain is 46 pC / 206 fC = 223


To convert histograms of summed ADC data (with 8ns sample time) to charge, multiply by 8 ns * 46 pC / 19.03 us = 19.3 fC


Garfield uses uA for signals, but I want to see the resulting histograms in adc units, for direct comparison with cosmics data. So... I need to convert my impulse response to input of 1 uA, ie use (1 / 17.2) * fitted function above as the transfer function.?? (Fitted function already includes current gain x 89).

The remaining gain factor needed to match garfield adc data to real life data is the gas gain.