| BCAL  
 
| BCAL  
 
| <span style="color:blue;">1.8 ns</span> / 70 ps/sqrt(E)
 
| <span style="color:blue;">1.8 ns</span> / 70 ps/sqrt(E)
| <span style="color:blue;">~19 MeV (pi0 mass); 20 MeV @ E=140 MeV</span>/ 5.4%/sqrt(E) + 2.3%
+
| <span style="color:blue;">~19 MeV (pi0 mass, E(pi0)>1.5 GeV)</span>/ 5.4%/sqrt(E) + 2.3%, 8.7 MeV (pi0 mass)
 
| <span style="color:blue;">6 cm (ADC), 35 cm (TDC) [z]</span> / ~8 mrad (trans.); 1.1 cm/sqrt(E) [z]
 
| <span style="color:blue;">6 cm (ADC), 35 cm (TDC) [z]</span> / ~8 mrad (trans.); 1.1 cm/sqrt(E) [z]
|
+
| <span style="color:blue;"> > 90%</span>
 
|-
 
|-
 
| CDC  
 
| CDC  
Line 169: Line 169:
 
| FCAL  
 
| FCAL  
 
| <span style="color:blue;">3.2 ns</span> / ~0.4 ns
 
| <span style="color:blue;">3.2 ns</span> / ~0.4 ns
| <span style="color:blue;">~25 MeV (pi0 mass); ~8% (beam e- E/p)</span> / 5.6%/sqrt(E) + 3.5%
+
| <span style="color:blue;">~25 MeV (pi0 mass); ~8% (beam e- E/p), ~20% @ 1 GeV</span> / 5.6%/sqrt(E) + 3.5%, 8.7 MeV (pi0 mass)
 
| / 6.4 mm/sqrt(E)
 
| / 6.4 mm/sqrt(E)
 
|
 
|
Line 186: Line 186:
 
|-
 
|-
 
| Start Counter  
 
| Start Counter  
| / 350 ps
+
| <span style="color:blue;">~480 ps</span> / 350 ps
 
| /  
 
| /  
 
| /
 
| /
|
+
| <span style="color:blue;">~90%</span>
 
|-
 
|-
 
| TAGH  
 
| TAGH  

Revision as of 10:35, 22 February 2015

Fall 2014 Data Calibration Status

This table summarizes the status of the calibrations that have been stored in the CCDB.

Last Updated -- 17 Feb. 2015

  • red - This category has not been calibrated
  • yellow - Calibrations have been partially done, or done with cosmic ray or other non-photon beam data
  • green - Calibrations have been done with photon beam data


Detector Base Time fADC E scale fADC gains fADC timing TDC timing TDC timewalk Low-level reco. obj. High-level reco. obj. Alignment
BCAL N/A 1 1
CDC N/A N/A 1
FCAL 1 N/A N/A
FDC N/A N/A
PS/PSC
Start Counter 1
TAGH 1 1
TAGM 1 1
TOF 1

Notes:

  • "Base time" refers to the relative timing between different detectors.
  • The fADC and TDC categories refer to per-channel calibrations.
  • The high-level reconstruction objects are the final inputs to a physics analysis. The low-level reconstruction objects are whatever objects are built from the calibrated hits and used to build the high-level objects.

Other Calibrations

CDC
Gas mixture
Time-to-distance
FDC
Gas mixture
Time-to-distance

Performance

Values obtained from data are shown in blue.

Detector Timing resolution Energy Resolution Spatial Resolution Efficiency
BCAL 1.8 ns / 70 ps/sqrt(E) ~19 MeV (pi0 mass, E(pi0)>1.5 GeV)/ 5.4%/sqrt(E) + 2.3%, 8.7 MeV (pi0 mass) 6 cm (ADC), 35 cm (TDC) [z] / ~8 mrad (trans.); 1.1 cm/sqrt(E) [z] > 90%
CDC / / ~150/250 um (far/close to wire) / ~200 um <~95%
FCAL 3.2 ns / ~0.4 ns ~25 MeV (pi0 mass); ~8% (beam e- E/p), ~20% @ 1 GeV / 5.6%/sqrt(E) + 3.5%, 8.7 MeV (pi0 mass) / 6.4 mm/sqrt(E)
FDC / / 150-250 um / ~200 um ~95%
PS/PSC / / /
Start Counter ~480 ps / 350 ps / / ~90%
TAGH 1.6 ns / / / ~85%
TAGM 1.6 ns / / / <~70%
TOF ~150 ps / ~90 ps / ~1.2 cm /

Notes:

  • When possible, the results are given as "Measured / Design"