Difference between revisions of "Charged Particle Tracking"
From GlueXWiki
Line 16: | Line 16: | ||
*[[BCAL|Barrel Calorimeter wiki page]] | *[[BCAL|Barrel Calorimeter wiki page]] | ||
*[[TOF|Forward Time-of-Flight wiki page]] | *[[TOF|Forward Time-of-Flight wiki page]] | ||
+ | |||
+ | == Documentation == | ||
+ | Here are the most recent documents relevant to charged particle tracking: | ||
+ | |||
=== The Most Up-to-date Documents on Tracking and PID === | === The Most Up-to-date Documents on Tracking and PID === | ||
* GlueX-doc-754 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=754 Forward Drift Chamber Technical Design Report] | * GlueX-doc-754 [http://argus.phys.uregina.ca/cgi-bin/private/DocDB/ShowDocument?docid=754 Forward Drift Chamber Technical Design Report] | ||
Line 35: | Line 39: | ||
− | |||
− | |||
=== Electronics === | === Electronics === |
Revision as of 15:06, 12 March 2008
Up to Reconstruction Software
Contents
Overview
Here is a page that gathers information on charged particle tracking in general for the Hall-D detector.
Meetings
- Tracking Meetings (Combined CDC/FDC)
- FDC Meetings
Chamber Design
- Central Drift Chamber wiki page
- Forward Drift Chambers wiki page
- Barrel Calorimeter wiki page
- Forward Time-of-Flight wiki page
Documentation
Here are the most recent documents relevant to charged particle tracking:
The Most Up-to-date Documents on Tracking and PID
- GlueX-doc-754 Forward Drift Chamber Technical Design Report
- GlueX-doc-855 Specification Document for FDC/CDC ADC (125 MSPS)
- GlueX-doc-866 Design goals for the Hall D detector and subsystems
- GlueX-doc-990 The GlueX Central Drift Chamber
- GlueX-doc-992 Start Counter Update
- GlueX-doc-994 TOF detector description for CDR
- GlueX-doc-995 Cable Characteristics for the Hall D FDC and CDC
- GlueX-doc-999 GlueX Physics and Detecor Performance Metrics
Software
- Offline Software wiki page
- GlueX-doc-956 The Lorentz Effect: Simulation and Reconstruction
- GlueX-doc-853 GlueX Simulation Geometry Version 4.0
- GlueX-doc-761 Track Fitting in GlueX: Development Report III
Electronics
- GlueX-doc-967 High Voltage Distribution for the Hall D CDC and FDC Detectors
- GlueX-doc-966 Low Voltage Distribution for the Hall D CDC and FDC Detectors
- GlueX-doc-855 Specification Document for FDC/CDC ADC (125 MSPS)
Talks
- GlueX-doc-996 DC and TOF Mechanical Design
- GlueX-doc-997 FDC Design
- GlueX-doc-998 Tracking & PID Electronics
- GlueX-doc-1000 Drift Chamber Simulation and Reconstruction for GlueX
Restricted
Motivating the tracking design parameters
Misc
These links are old and the information needs to be updated