Difference between revisions of "Commissioning Calibration Data"

From GlueXWiki
Jump to: navigation, search
(Fall 2015)
(Fall 2015)
Line 3: Line 3:
  
 
Calibration data needs as of Sept. 22, 2015
 
Calibration data needs as of Sept. 22, 2015
 
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 50: Line 49:
 
| Start Counter
 
| Start Counter
 
| style="background-color: yellow;" | More Needed
 
| style="background-color: yellow;" | More Needed
|  
+
| 75 M
 
| 20x
 
| 20x
 
|  
 
|  
|
+
| basic calibrations are good, more refinement possible
 
|-  
 
|-  
 
| TAGH
 
| TAGH
Line 65: Line 64:
 
| style="background-color: yellow;" | More Needed
 
| style="background-color: yellow;" | More Needed
 
|  
 
|  
| 10M - 50M
+
| 10 M - 50 M
 
|
 
|
 
|
 
|

Revision as of 18:24, 22 September 2015

Fall 2015

Calibration data needs as of Sept. 22, 2015

Detector Status Data in Hand Est. Data Needed Est. Running Time Notes
BCAL More Needed 100x
CDC More Needed
FCAL More Needed 10x
FDC More Needed 3 shifts, 10^-4 radiator, 100 nA, no field needed
PS/PSC OK
Start Counter More Needed 75 M 20x basic calibrations are good, more refinement possible
TAGH OK
TAGM More Needed 10 M - 50 M
TOF OK need to verify stability of calibrations with more data