Calibration data needs as of Sept. 22, 2015
+
Calibration data needs as of Oct. 22, 2015
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 28: Line 28:
 
| FCAL
 
| FCAL
 
| style="background-color: yellow;" | More Needed
 
| style="background-color: yellow;" | More Needed
| 18k
+
| 125k
 
| 10x
 
| 10x
 
|
 
|
|
+
| pi0 cluster energy > 1 GeV
 
|-  
 
|-  
 
| FDC
 
| FDC
Line 75: Line 75:
 
| need to verify stability of calibrations with more data
 
| need to verify stability of calibrations with more data
 
|}
 
|}
 +
 +
=== Notes ===
 +
 +
* Data needed depends strongly on S/B, especially for calorimeters
 +
 +
== Scaling from 6 GeV to 12 GeV ===
 +
 +
* 6 GeV settings: 5.5 GeV e- beam, 50 um diamond radiator, 5 mm collimator, E(gam) = 2 - 5.5 GeV
 +
* 12 GeV settings: 12 GeV e- beam, 20 um diamond radiator, 3.4 mm collimator, E(gam) = 7 - 12 GeV

Revision as of 13:51, 6 October 2015

Fall 2015

Calibration data needs as of Oct. 22, 2015

Detector Status Data in Hand Est. Data Needed Est. Running Time Notes
BCAL More Needed 1.3 M (pi0) 100x pi0 numbers assuming cluster > 350 MeV
CDC More Needed
FCAL More Needed 125k 10x pi0 cluster energy > 1 GeV
FDC More Needed 3 shifts, 10^-4 radiator, 100 nA, no field needed
PS/PSC OK
Start Counter More Needed 75 M 20x basic calibrations are good, more refinement possible
TAGH OK
TAGM More Needed 10 M - 50 M
TOF OK need to verify stability of calibrations with more data

Notes

  • Data needed depends strongly on S/B, especially for calorimeters

Scaling from 6 GeV to 12 GeV =

  • 6 GeV settings: 5.5 GeV e- beam, 50 um diamond radiator, 5 mm collimator, E(gam) = 2 - 5.5 GeV
  • 12 GeV settings: 12 GeV e- beam, 20 um diamond radiator, 3.4 mm collimator, E(gam) = 7 - 12 GeV