Difference between revisions of "Commissioning Calibration Data"

From GlueXWiki
Jump to: navigation, search
(Final States Used For Calibrations)
(Final States Used For Calibrations)
Line 8: Line 8:
 
{| class="wikitable"
 
{| class="wikitable"
 
! Reaction  
 
! Reaction  
!  Cross Section @ E<sub>&gamma;</sub> ~ 9 GeV (&mu;b)
+
!  Cross Section @ E<sub>&gamma;</sub> ~ 9 GeV
! Cross Section @ E<sub>&gamma;</sub> ~ 5 GeV (&mu;b)
+
! Cross Section @ E<sub>&gamma;</sub> ~ 5 GeV  
 
|-
 
|-
 
| p &gamma; &rarr; p &pi;<sup>0</sup>
 
| p &gamma; &rarr; p &pi;<sup>0</sup>
Line 20: Line 20:
 
|-
 
|-
 
| p &gamma; &rarr; p &rho;<sup>0</sup> ; &rho;<sup>0</sup> &rarr; &pi;<sup>+</sup> &pi;<sup>-</sup>
 
| p &gamma; &rarr; p &rho;<sup>0</sup> ; &rho;<sup>0</sup> &rarr; &pi;<sup>+</sup> &pi;<sup>-</sup>
| style="text-align:center;" | 13.5 &plusmn; 0.5 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 13.5 &plusmn; 0.5 &mu;b ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
| style="text-align:center;" | 15.9 &plusmn; 0.7 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 15.9 &plusmn; 0.7 &mu;b ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
 
|-
 
|-
 
| p &gamma; &rarr; p &omega; ; &omega; &rarr; &gamma;  &pi;<sup>0</sup>
 
| p &gamma; &rarr; p &omega; ; &omega; &rarr; &gamma;  &pi;<sup>0</sup>
| style="text-align:center;" | 0.16 &plusmn; 0.02 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 160 &plusmn; 20 nb ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
| style="text-align:center;" | 0.25 &plusmn; 0.02 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 250 &plusmn; 20 nb ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
 
|-
 
|-
 
| p &gamma; &rarr; p &omega; ; &omega; &rarr; &pi;<sup>+</sup> &pi;<sup>-</sup> &pi;<sup>0</sup>
 
| p &gamma; &rarr; p &omega; ; &omega; &rarr; &pi;<sup>+</sup> &pi;<sup>-</sup> &pi;<sup>0</sup>
| style="text-align:center;" | 1.7 &plusmn; 0.3 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 1.7 &plusmn; 0.3 &mu;b ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
| style="text-align:center;" | 2.7 &plusmn; 0.3 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 2.7 &plusmn; 0.3 &mu;b ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
 
|-
 
|-
 
| p &gamma; &rarr; p &phi; ; &phi; &rarr; K<sup>+</sup> K<sup>-</sup>
 
| p &gamma; &rarr; p &phi; ; &phi; &rarr; K<sup>+</sup> K<sup>-</sup>
| style="text-align:center;" | 0.27 &plusmn; 0.03 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 270 &plusmn; 30 nb ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
| style="text-align:center;" | 0.20 &plusmn; 0.04 ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
+
| style="text-align:center;" | 200 &plusmn; 40 nb ([http://journals.aps.org/prd/pdf/10.1103/PhysRevD.7.3150 ref])
 
|-
 
|-
 
| p &gamma; &rarr; p K<sub>S</sub> + X
 
| p &gamma; &rarr; p K<sub>S</sub> + X

Revision as of 13:36, 3 November 2015

Final States Used For Calibrations

This is a partial list of final states that can be used for calibrations. Fully reconstructed reactions give clean inputs to calibrations procedures. It would be helpful to have rate/efficiency studies for these reactions.

Assuming electron beam @ 12 GeV

Reaction Cross Section @ Eγ ~ 9 GeV Cross Section @ Eγ ~ 5 GeV
p γ → p π0 ~180 nb (ref) ~400 nb (ref)
p γ → p η ; η → γ γ ~30 nb (ref)
p γ → p ρ0 ; ρ0 → π+ π- 13.5 ± 0.5 μb (ref) 15.9 ± 0.7 μb (ref)
p γ → p ω ; ω → γ π0 160 ± 20 nb (ref) 250 ± 20 nb (ref)
p γ → p ω ; ω → π+ π- π0 1.7 ± 0.3 μb (ref) 2.7 ± 0.3 μb (ref)
p γ → p φ ; φ → K+ K- 270 ± 30 nb (ref) 200 ± 40 nb (ref)
p γ → p KS + X
p γ → Λ K+ ; Λ → p π-

Fall 2015

Calibration data needs as of Oct. 6, 2015

Detector Status Data in Hand Est. Data Needed Est. Running Time Notes
BCAL More Needed 130k pi0 25-50x ~43 - 85 hr pi0 cluster energy > 750 MeV
CDC OK 350 M cosmics
FCAL More Needed 125k pi0 10x ~1 - 2 hr pi0 cluster energy > 1 GeV
FDC OK 3 shifts, 10^-4 radiator, 100 nA, no field needed
PS/PSC OK
Start Counter More Needed 80 M tracks 10x ~4 hr basic calibrations are good, more refinement possible
TAGH OK
TAGM More Needed 10 M - 50 M 4 hr
TOF OK need to verify stability of calibrations with more data

Projected running times scaled up from conditions in Run 3185. Assumes 12 GeV e- beam with 100 nA current.

Notes

  • Data needed depends strongly on S/B, especially for calorimeters.
  • Lowering thresholds can have a large effect, too
  • SC run list: 2931, 2932, 2933, 2934
  • BCAL/FCAL run list: 2931, 3185 [diamond]; 3079, 3179, 3180, 3182, 3199, 3200, 3201, 3217 [1x10-4 RL amorphous]
    • Scaling factor: diamond = 8 x amorphous
  • CDC/FDC will need more data to calibrate fADC125 algorithm when it's deployed.

Scaling from 6 GeV to 12 GeV

  • 6 GeV settings: 5.5 GeV e- beam, 50 um diamond radiator, 5 mm collimator, E(gam) = 2 - 5.5 GeV
  • 12 GeV settings: 12 GeV e- beam, 20 um diamond radiator, 3.4 mm collimator, E(gam) = 7 - 12 GeV
  • rate(12 GeV) / rate(6 GeV) ~ 80% [using cobrems in bggen, incl. plastic target on nose removal in 12 GeV era].
  • Geometrical factors: (12 GeV/6 GeV)
    • SC - ~1x (straight section drives needs)
    • BCAL - ~1x (both photons in BCAL)
    • FCAL - ~8x (both photons in FCAL)

Runs

Run Events Run Time (hr) Evts/hr
3185 19.9 M 2.2 9.0 M
2931 74.6 M 7.4 10.1 M
2932 0.4 M 0.1 4.0 M
2933 3.0 M 0.7 4.3 M
2934 3.6 M 1.5 2.4 M
3079 25.9 M 7.0 3.7 M
3179 14.6 M 1.75 8.3 M
3180 41.3 M 4.8 8.6 M
3199 4.4 M 3.0 1.5 M
3200 12.5 M 9.0 1.4 M
3201 5.6 M 5.4 1.0 M
3217 10.8 M 6.3 1.7 M