Difference between revisions of "Data Monitoring Database"
From GlueXWiki
Line 11: | Line 11: | ||
* Monitoring data tables | * Monitoring data tables | ||
** Common info - run id, version id, # of events recorded in detector | ** Common info - run id, version id, # of events recorded in detector | ||
− | ** TAGH - hit rate (mean, sigma), hit times (mean, sigma) | + | ** TAGH - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** TAGM - hit rate (mean, sigma), hit times (mean, sigma) | + | ** TAGM - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** SC - hit rate (mean, sigma), hit times (mean, sigma) | + | ** SC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** CDC - hit rate (mean, sigma), hit times (mean, sigma) | + | ** CDC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** FDC - hit rate (mean, sigma), hit times (mean, sigma) | + | ** FDC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** TOF - hit rate (mean, sigma), hit times (mean, sigma) | + | ** TOF - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** BCAL - hit rate (mean, sigma), hit times (mean, sigma) | + | ** BCAL - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** FCAL - hit rate (mean, sigma), hit times (mean, sigma) | + | ** FCAL - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
− | ** PS - hit rate (mean, sigma), hit times (mean, sigma) | + | ** PS - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma) |
** ANALYSIS - tracks (mean, sigma); neutrals (mean, sigma), avg. resolutions | ** ANALYSIS - tracks (mean, sigma); neutrals (mean, sigma), avg. resolutions | ||
Revision as of 23:28, 23 September 2014
Draft Requirements for data quality monitoring database
The main purpose of this database is to display time series summaries of variables useful for data quality monitoring
Tables
- Metadata tables
- Runs - run id (internal), run number, run start time/date, run stop time/date, # of events, nominal beam current, nominal beam energy, target type, target location (?), trigger configuration (e.g. a file name), solenoid field current, radiator.
- Versions - version id (internal), release, CCDB version, timestamp, data type
- Monitoring data tables
- Common info - run id, version id, # of events recorded in detector
- TAGH - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- TAGM - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- SC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- CDC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- FDC - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- TOF - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- BCAL - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- FCAL - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- PS - hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- ANALYSIS - tracks (mean, sigma); neutrals (mean, sigma), avg. resolutions
Parameters
- Data types - types of monitoring data that we are saving (online, offline, MC) [better terms?]
- Data version