Data Monitoring Database
From GlueXWiki
Draft Requirements for data quality monitoring database
The main purpose of this database is to display time series summaries of variables useful for data quality monitoring
Contents
Tables =
Metadata tables
- Runs - run id (internal), run number, run start time/date, run stop time/date, # of events, nominal beam current, nominal beam energy, target type, target location (?), trigger configuration (e.g. a file name), solenoid field current, radiator.
- Versions - version id (internal), release, CCDB version, timestamp, data type
Raw Data Tables
- Common info - run id, version id, # of events recorded in detector
- TAGH - pedestals, hit counts (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- TAGM - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- SC - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- CDC - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- FDC - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- TOF - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- BCAL - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- FCAL - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
- PS - pedestals, hit rate (mean, sigma), hit times (mean, sigma), minimum ionizing peak energies (mean, sigma)
Reconstruction Data Tables
- Tracking: # tracks (by PID), avg. resolutions
- Showers: # showers, avg. resolutions
- Beam Photons: # photons
- SC/TOF: # hits
Parameters
- Data types - types of monitoring data that we are saving (online, offline, MC) [better terms?]
- Data version