Discrepancies between CDC firmware output and emulation output, repeatfree=no repeated pairs
Run hits repeatfree hits diffs time q pedestal amplitude integral overflow count readout
10954 28658293 24179315 12394 61 0 1 12326 6 0 CDC
10956 87414131 73914777 145176 107559 275 4 37530 12672 0 CDC
10957 19196556 16340197 33186 24069 59 3 9086 2868 0 CDC & FDC

NB hits with repeated pairs are not necessarily an error, it was just simpler to exclude all of them

runs 10954 and 10956 time errors
Cdc run10954 dtt.png
Cdc run10956 dtt.png
Cdc run10954 dtch.png
Cdc run10956 dtch.png